My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Facility Inspection <br />Name: Escalon Mini mart address: 1097 Yosemite Ave, Escalon Date: Jan 13, 2012 <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine and Annual Monitoring System Certification <br />202. Current approved copies of the Monitoring and Response Plans were not found on site. The <br />Monitoring and Response Plans must be current and approved by EHD. <br />- Copies made and kept on site. <br />108. Secondary containment was not performed in a timely manner. Secondary containment testing <br />was last performed on 11/08/2008 and the next tri -annual secondary containment testing was due by <br />11/2011. Testing has not been completed and is three months past due. Secondary containment <br />testing is required once every 36 months. Immediately schedule this test and provide 48 hours <br />notification to the EHD. <br />In addition, the last secondary containment testing indicated a failure in the under dispenser containment <br />(UDC) 1/2, 3/4, 5/6, 7/8, the 87 secondary product lines run #2, #3, #4 and 91 secondary line run #1. All <br />secondary containment for the UST system must be tight. Immediately have a properly licensed, trained <br />and certified contractor replace or repair the failed component under permit and inspection of EHD and <br />submit passing results to this office. An permit has been taken out and approved for the repairs under <br />SR0062373 but repair date has not been set. <br />113. Failed to inform EHD of change of designated operators (DO) within 30 days. A designated <br />operator Steve Zwahlen (exp 05/01/12) from Franzen -Hill performed monthly visual inspection reports <br />for this facility for the month of November - December 2010, January - March 2011. Designated operator <br />Chris Deyoung (exp 08/08/13) from Franzen -Hill performed monthly visual inspection reports for this <br />facility for the month of August 2011. Designated operator Tyne Hardeman (exp 11/11/13) from <br />Franzen -Hill performed visual monthly inspection report for the month of December 2011. Any changes <br />in designated operators shall be reported to EHD within 30 days. Submit notification to EHD identifying <br />all designated operators for this facility within 30 days of receiving this report. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: Received By: Title: �� L <br />=HD 23-02 Rev 0910 11 Paae 3 UST INSPECTION REPORT <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />113iennial tightness test of gravity piping not performed (pre -January 1, 1984) (M7) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M7) <br />Other Violations <br />999 <br />Other: <br />See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine and Annual Monitoring System Certification <br />202. Current approved copies of the Monitoring and Response Plans were not found on site. The <br />Monitoring and Response Plans must be current and approved by EHD. <br />- Copies made and kept on site. <br />108. Secondary containment was not performed in a timely manner. Secondary containment testing <br />was last performed on 11/08/2008 and the next tri -annual secondary containment testing was due by <br />11/2011. Testing has not been completed and is three months past due. Secondary containment <br />testing is required once every 36 months. Immediately schedule this test and provide 48 hours <br />notification to the EHD. <br />In addition, the last secondary containment testing indicated a failure in the under dispenser containment <br />(UDC) 1/2, 3/4, 5/6, 7/8, the 87 secondary product lines run #2, #3, #4 and 91 secondary line run #1. All <br />secondary containment for the UST system must be tight. Immediately have a properly licensed, trained <br />and certified contractor replace or repair the failed component under permit and inspection of EHD and <br />submit passing results to this office. An permit has been taken out and approved for the repairs under <br />SR0062373 but repair date has not been set. <br />113. Failed to inform EHD of change of designated operators (DO) within 30 days. A designated <br />operator Steve Zwahlen (exp 05/01/12) from Franzen -Hill performed monthly visual inspection reports <br />for this facility for the month of November - December 2010, January - March 2011. Designated operator <br />Chris Deyoung (exp 08/08/13) from Franzen -Hill performed monthly visual inspection reports for this <br />facility for the month of August 2011. Designated operator Tyne Hardeman (exp 11/11/13) from <br />Franzen -Hill performed visual monthly inspection report for the month of December 2011. Any changes <br />in designated operators shall be reported to EHD within 30 days. Submit notification to EHD identifying <br />all designated operators for this facility within 30 days of receiving this report. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: Received By: Title: �� L <br />=HD 23-02 Rev 0910 11 Paae 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.