COMPLIANCE INFO_2010-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY 41 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.o[g/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Facility Inspection <br />Name: Escalon Mini Mart Address: 1097 Yosemite Ave., Escalon Date: Sep 9, 2011 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and S Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M7) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (MI) <br />Other Violations <br />999 1 10ther: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR -Notice to Comply) <br />FOLLOW UP INSPECTION <br />Class II violations: (113, 201, 204, 205, 206, 307) <br />113. A new designated operator began conducting the monthly designated operator inspections in April <br />2011 and notification was not provided to the EHD within 30 days of the change. Any changes shall be <br />reported to the EHD with 30 days. An updated notification was submitted at the time of inspection. <br />REPEAT VIOLATION <br />201. The alarms from February 20, 2011 (unleaded sump) and February 25, 2011 (dispenser 7-8) were <br />not documented in the alarm log. Maintenance records for the response to these alarms were not found <br />on site. These records shall be kept on site for at least 3 years. Immediately locate and maintain the <br />maintenance records on site and submit a statement documenting the corrective actions taken in <br />response to these alarms to the EHD by October 9, 2011. <br />REPEAT VIOLATION <br />204. The designated operator failed to document all the alarms from the attached alarm history on the <br />designated operator monthly inspection reports and failed to check that they were responded to <br />appropriately. The missing alarms include: February 20, 2011 (unleaded sump), January 29, 2010 <br />(dispenser 1/2, 3/4, 5/6), January 28, 2010 (unleaded sump), April 12, 2010 (dispenser 7/8), and <br />December 16, 2009 (dispenser 7/8). During the monthly inspection, the designated operator shall <br />review the alarm history for the previous month, check that each alarm was documented and responded <br />to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />REPEAT VIOLATION <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TME AT EHD'S CURRENT HOURLY RATE. <br />o w (v <br />EHD 23-02 I6 09011'f1 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.