Laserfiche WebLink
: <br />7. UNDER -DISPENSER CONTAINMENT gjpCj TESTING <br />Test Method Developed By: ❑ UDC Manufacturer X Industry Standard ❑ Professional Engrg <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />icy <br />❑ Other (Specify) F r,r <br />Test Equipment Used: Incon TS STS Equipment Resolution: .002 <br />ffiffiffiffillyffiffilmne <br />UDC # 1/2 UDC # 3/4 UDC # 5/6 UDC # 7/8 <br />UDC Manufacturer: Smith's Smith's Smith's Smith's <br />UDC Material: Fiberglass <br />Fiberglass Fiberglass Fiber ass <br />UDC Depth: 35" <br />35" 35" 35" <br />Height from UDC Bottom to Top <br />12" <br />12" 12" 12" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />15" <br />15" 15" 15" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Clean <br />Clean Clean Clean <br />testing: <br />Portion of UDC Tested' <br />Full <br />Full Full Full <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />product and water)?` <br />Turbine shutdown response time <br />Is system programmed for fail- <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No [INA <br />safe shutdown?* <br />Was fail-safe verified to be <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />15 min. <br />15 min. 15 min. 15 min. <br />starting test <br />Test Start Time: <br />10:47am <br />10:47am 11:44am 10:47am <br />Initial Reading (RI): <br />2.1272 <br />3.0541 3.1503 3.6604 <br />Test End Time: <br />11:03am <br />11:03am 11:59am 11:03am <br />Final Reading (RF): <br />2.1274 <br />3.0551 3.1500 3.6605 <br />Test Duration: <br />15 min. <br />15 min. 15 min. 15 min. <br />Change in Reading (RF-Ri): <br />+.0002 <br />-.0010 -.0003 -.0001 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 .002 .002 <br />Test Result: <br />X Pass U Fail <br />X Pass ' U Fail X Pass < U Fall X Pass U Fail <br />Was sensor removed for testing? <br />X Yes []No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No 0 NA X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to ppy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />