My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R � <br />4 <br />Page 4 of 7 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: 0 Sump Manufacturer X Industry Standard 0 Professional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure ❑ Vacuum X Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Incon TS STS <br />Equipment Resolution: .002 <br />Sump # 87 <br />Sump # 91' <br />r, <br />Sump Diameter: 42" <br />42", <br />Sump Depth: <br />4.5' <br />4.5' <br />Sump Material: <br />Fiber/Steel <br />Fiber/Steel <br />J„ <br />Height from Tank To to To of <br />p <br />12" <br />12" <br />N1 H <br />Highest Piping Penetration: <br />a <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />10" <br />10" <br />Condition of sump prior to testing: <br />Dusty <br />Dusty <br />Portion of Sump Tested' <br />Full <br />Full <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />0 Yes ❑ No 0 NA <br />0 Yes 0 No ❑ NA <br />product and water)?' <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />0 Yes ❑ No ❑ NA <br />0 Yes 0 No ❑ NA <br />shutdown?` <br />Was fail-safe verified to be <br />D Yes ❑ No ❑ NA <br />0 Yes ❑ No 0 NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />15 min <br />15 min <br />test: <br />Test Start Time: <br />12:40pm <br />11:44am <br />Initial Reading (Ri): <br />2.9820 <br />3.9979 <br />Test End Time: <br />12:56pm <br />11:59am <br />Final Reading (RF): <br />2.9824 <br />3.9982 <br />Test Duration: <br />15 min <br />15 min <br />Change in Reading (RF-Ri): <br />+.0004 <br />+.0003 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />Test Result: ' <br />X Pass U Fail <br />X Pass U Fail <br />Was sensor removed for testing? <br />X Yes 0 No ❑ NA <br />X Yes 0 No ❑ NA <br />Was sensor properly replaced and <br />X Yes 0 No DNA <br />X Yes ❑ No U NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.