Laserfiche WebLink
INDIVIDU ANK/LINE/LEAK DETECTOR TE a—PORTNDE <br /> NDE E VIRONE L CORPORATION <br /> TEST DATE: December 1, 1994 WORK ORDER NUMBER: 963222 <br /> • CLIENT. TOSCO NORTHWEST COMPANY SITE: BP 1-1195 <br /> 'T' w <br /> Tank ID: i Bottom to top fill in inches: 132.0 <br /> Product: PLUS Bottom to grade fill in inches: 139.0 <br /> Capacity in gallons: 8,000 Fill pipe length in inches: 40.0 <br /> Diameter in inches: 92.00 Fill pipe diameter in inches: 4.0 <br /> Length in inches: 282 Stage I vapor recovery: COAX <br /> Material: FIBERGLASS Stage II vapor recovery: BALANCE <br /> Tank: No <br /> Manifolded Vent: No <br /> V/R: No <br /> TANK TEST RESULTS LEMS tIE'CECTt1Ft RESULTS <br /> Test method: Alert 4000 New/passed Failed/replaced <br /> Psi at tank bottom: 1.65 detector detector <br /> Fluid level in inches: 61.50 Test method: FTA <br /> UFT/OFT: IIFT Make: RED JACKET <br /> Fluid volume in gallons: 5,683 <br /> Model: X.L.D. <br /> Water level in inches: 0.00 <br /> S/N: 101937933 <br /> Test time: 21:42-00:22 <br /> Open time in sec: 3.00 <br /> Number of thermisters: <br /> Spec'Ific gravity: 0.748 Holding psi: 15 <br /> Resiliency cc: 950 <br /> Water table depth in inches: 160.00 <br /> Test leak rate i 189.0 <br /> Determined by(method): MONTR WELL <br /> Leak rate in gph: -0.006 Metering ng psis: l0 <br /> RESULT: PASS Calib.leak in gph: 3.00 <br /> RESULT. PASS <br /> O{ tME� ENTS <br /> UC A�aE TEST RESt LTS Lt11E T t"RE$l3LTS <br /> Test method: Alert 1050 Material: <br /> Test time: 02:15-02:25 FIBERGLASS <br /> Diameter(in): 2.0 <br /> Ullage volume: 2,317 <br /> Length(ft): 70.0 <br /> Ullage pressure: 1.50 Test psi: 5o <br /> RESULT: PASS Bleedback cc: 80 <br /> DATA FOR UTS-4T ONLY: Test time(min): 30 <br /> Time of test 1: Test 1:start time: 22:39 <br /> finish psi: 50 <br /> Temperature: vol change cc: io <br /> Flow rate(cfh): Test 2:start time: 22-49 <br /> Time of test 2: finish psi: so <br /> vol change cc: o <br /> Temperature: Test 3:start time: 22:59 <br /> Flow rate(cfh): finish psi: 5o <br /> Time of test 3: vol change cc: o <br /> Temperature: Final gph: 0.005 <br /> Flow rate(cfh): RESULT: PASS <br /> Test type:AcuRite <br /> MENTS Pump type: PRESSURE Pump make: RED JACKET <br /> GC3MMEt+JTa <br /> 8906 WALL STREET SUITE 306 AUSTIN TEXAS 78754 512 719-4633 <br />