My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2003-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 2:05:37 PM
Creation date
6/3/2020 9:50:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2010
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_2003-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> Site A Date of Testing/Servicing: <br /> A Results of Testing/Servicing <br /> Software Version Installed: �-- <br /> Complete the fo 'ng checklist: <br /> GKYes ❑ No* Is the audible alarmoperational? <br /> (yYes ❑ No* IS the visual alarm operational? <br /> ❑ Yes RrNo* Were all sensors visually msWctrA fimetionally tested,and confirmed "oral? <br /> ( Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their pgM operation?_ <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> [2r-Ft/A operational? <br /> W Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors <br /> initiate positive shut-down? (Check all that apply) eSump/Trench Sensors; Dispenser Containment <br /> Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ®'Yes, ❑No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> [jrN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating property? If so,at what percent of tank capacity does the alarm trigger? ?'???% <br /> ❑ Yes* No Was any monitoring equipment rep ? If yes, identify specific sensors, probes, or other equipment <br /> repla and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* T rNo Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product-, ❑Water. If yes,describe causes in Section E,below. <br /> Yes ❑ No* Was monitoring set-up reviewed to ensure ffcEg settings? <br /> Yes ❑ No* Is all monitorin Ld menta rational per man is ons? <br /> *In Section E below,describe how and when these deficiencies were or will be co <br /> E. Comments: � d�<- s ��' �n ! n, r- ,✓ ,� '�`" t36= i� ic��y ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.