My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:21:17 PM
Creation date
6/3/2020 9:50:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />SWRCB, January 2002 <br />4. TANK ANNULAR TESTING <br />• Page of <br />Test Method Developed By: x Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure x Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Dwyer Manometer <br />/ _._ _..��.. 3`%�'.>-•r`"d��, � ,_ K- <br />Tank # 1 Tank # <br />Equipment Resolution: +/- 2% <br />3 z ,�"'fb'�.+&;�"�`,'; ��4JSCe '�ii' .fi�'_ _�iY 'P}.vt hc�e'v. <br />Tank # <br />Tank # <br />Is Tank Exempt From Testing?' x Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />Tank Capacity: 10,000 <br />Tank Material: Fiberglass <br />Tank Manufacturer: Unknown <br />Product Stored: Diesel <br />Wait time between applying <br />pressure/vacuum/water and 30 min <br />starting test: <br />30 min <br />30 min <br />30 min <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: 1 hour <br />1 hour <br />1 hour <br />1 hour <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: No less than I" <br />No less than 1" <br />No less than I" <br />No less than I" <br />Test Result: ❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />Was sensor properly replaced and x Yes ❑ No ❑ NA <br />verified functional after testing? <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Annular space is brine filled <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />tactino ft` ];Cnrn;a Cnrla Titles TI Carfinn 7AIW7 VA. k <br />