SWRCB, January 2002 <br />..1,. / I I I>. 1 <br />10 Page of <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Systems <br />Equipment Resolution: .005/30 min <br />Sump # 1 <br />Sump <br />Sump # <br />Sump # <br />Sump Diameter: <br />42" <br />Sump Depth: <br />50" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />24„ <br />Height from Tank Top to Lowest <br />33„ <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Dry <br />Portion of Sump Tested' <br />2" above <br />Highest piping <br />penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />x Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />roduct and water)?* <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown?' <br />x Yes ❑ No ElNA <br />❑Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />o erational?' <br />❑Yes x No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑Yes ElNo ElNA <br />❑Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5 min <br />5 min <br />5 min <br />5 min <br />test: <br />Test Start Time: <br />9:20 <br />Initial Reading (RI): <br />.00" <br />.00" <br />.00" <br />.00" <br />Test End Time: <br />9:50 <br />Final Reading (RF): <br />.00 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF -RI): <br />.00 <br />Pass/Fail Threshold or Criteria: <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />Test Result: <br />x Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes x No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />x Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />