My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:56:44 PM
Creation date
6/3/2020 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPAINSER CONTAINMENTODC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descriotion Diso # 8 Sat <br />UDC manufacturer <br />Total Containment <br />UDC material <br />Poly <br />UDC depth (inches) <br />38" <br />Height from UDC bottom to highest <br />piping penetration <br />8" <br />Height from UDC bottom to lowest <br />electrical penetration <br />12" <br />Condition of UDC prior to testing <br />Dry <br />Portion of UDC tested <br />Entire <br />Type of shut -down present <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Depth of water level from UDC bottom (in.) <br />14 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />Test start time <br />2:17 PM <br />Initial Probe Reading <br />2.6691 <br />Test end time <br />2:32 PM <br />Final Probe Reading <br />2.6703 <br />Test duration (hr:min) <br />0:15 <br />Change in water level (± 0.0000 inches) <br />0.0012 <br />Pass/Fail threshold (±0.0020 inches / } Hr.) <br />0.0020 <br />TEST RESULT <br />PASS <br />Comments: <br />© 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.