UNDER DISPASER CONTAINMENT fADC) TESTING <br />Test Method By: O Manufacturer <br />Test Method Uses: O Pressure <br />Measuring Equipment Used: INCON <br />0 Industry Standard o Professional Engr o Other (see below) <br />O Vacuum • Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 1/2 <br />Disp # 3/4 <br />Disp # 5/6 <br />Disp # 7/8 <br />0:05 <br />UDC manufacturer <br />Total Containment <br />Total Containment <br />Total Containment <br />Total Containment <br />2:17 PM <br />Initial Probe Reading <br />UDC material <br />Poly <br />Poly <br />Poly <br />Poly <br />1:31 PM <br />1:31 PM <br />UDC depth (inches) <br />38 <br />38 <br />38 <br />38 <br />2.7369 <br />6.3356 <br />Height from UDC bottom to highest <br />piping penetration <br />6 <br />10 <br />14 <br />13 <br />Type of shut -down present <br />Sensor <br />Height from UDC bottom to lowest <br />electrical penetration <br />10 <br />6 <br />10 <br />10 <br />Yes <br />Yes <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Yes <br />Port <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />12 <br />12 <br />16 <br />16 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />1:16 PM <br />1:16 PM <br />2:17 PM <br />2:17 PM <br />Initial Probe Reading <br />4.4532 <br />3.7776 <br />2.7533 <br />6.3543 <br />Test end time <br />1:31 PM <br />1:31 PM <br />2:32 PM <br />2:32 PM <br />Final Probe Reading <br />4.3051 <br />3.7790 <br />2.7369 <br />6.3356 <br />ion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />12 <br />12 <br />16 <br />16 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />1:16 PM <br />1:16 PM <br />2:17 PM <br />2:17 PM <br />Initial Probe Reading <br />4.4532 <br />3.7776 <br />2.7533 <br />6.3543 <br />Test end time <br />1:31 PM <br />1:31 PM <br />2:32 PM <br />2:32 PM <br />Final Probe Reading <br />4.3051 <br />3.7790 <br />2.7369 <br />6.3356 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.1481 <br />0.0014 <br />-0.0164 <br />-0.0187 <br />Pass/Fail threshold (10.0020 inches Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />FAIL <br />PASS <br />FAIL <br />FAIL <br />© 2006 Walton Engineering, Inc. <br />