COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:58:56 PM
Creation date
6/3/2020 9:50:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br />UNIFIED PROGRAM CONSOLIDATED FORiM <br />UNDERGROUND STORAGE TANK <br />NIONITORING PLAN — (Page 2 of 2) <br />VI. UNDER DISPENSER CONTAINMENT (UDC) MONITORING alappll <br />hat <br />a l <br />y. <br />UDC N40NITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br />N 1. CONTINUOUS ELECTRONIC MONITORING ❑ 2. FLOAT AND CHAIN ASSEMBLY [] 3. ELECTRONIC STAND-ALONE <br />490'540-. <br />❑ 4. NO DISPENSERS ❑ 99. OTHER (Specify) <br />490•54b <br />LEAK MONITOR iviANUFACTURER: Veeder Root 491-11. MODEL #: TLS -350 <br />490-S& <br />LEAK SENSOR MANUFACTURER: Veeder Root 494-57. MODEL #(S): 0794380-208 <br />490-5s. <br />DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL. ALARMS. ® a. YES ❑ b. NO <br />490•$9 <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. N a. YES ❑ i7. NO <br />490-61. <br />FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. N a. YES ❑ b. NO <br />490-61 <br />UDC MONITORiNG STOPS TETE FLOW OF PRODUCT AT THE DISPENSER. ® it. YES ❑ b. NO <br />451 sz <br />UDC CONSTRUCTION IS: ® 1. SINGLE WALL ❑ 2. DOUBLE WALL <br />490-63. <br />IF DOUBLE WALL: <br />490-641 <br />UDC INTERSTITIAL SPACE IS MONITORED BY ❑ a. LIQUID ❑ b. PRESSURE ❑ c. VACUUM <br />A LEAK WTTI iIN THF, SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a. YES ❑ b. NO <br />494-64b <br />VII. PERIODIC SYSTEM TESTING <br />❑ 1. ELI) TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br />494.65. <br />LEAK DETECTION ELD MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. pAccit 2644.tj <br />® 2. SECONDARY CONTAINMENT COMPONENTS ARF TESTED EVERY 36 N•IONTHS. <br />444 6G <br />® 3. SPILL BUCKETS ARE TESTED ANNUALLY. <br />490.67. <br />VIII, RECORD IMEEPING <br />The following monitoring/maintenance records are kept for this facility: <br />490-68 <br />N a. ALARM LOGS ❑ b. VISUAL INSPECTION RECORDS ❑ c. TANK INTEGRITY TESTING RESULTS <br />❑ d. SIR TFSTING RESULTS (and supporting documentation records) ❑ e. TANK GAUGING RESULTS (and supporting documentation records) <br />❑ f. ATG TESTING RESULTS (and supporting documentation records) ❑ g. CORROSION PROTECTION 60 -DAY LOGS <br />® h. E UiPkIFNT MAINTENANCE AND CALIBRATION RECORDS <br />IX. TRAINING <br />® Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties: <br />490.693 <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITYE (Check all that apply) <br />N THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />494.69b. <br />N OPERATING MANUALS FOR ELECTRONIC NIONI TORiNG EQUIPMENT (Required) <br />490.69c. <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />490•69d <br />❑ CALIFORNIA UNDERGROUND STORAGE "TANK LAV <br />4W69e <br />❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />490-69f <br />STATISTICAL INVENTORY RECONCILIATION" <br />491-69K. <br />❑ SWRCB PUBLICATION: "UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" <br />❑ OTHER (Specify): <br />4 45D.69io.c9;. <br />® This facility has a "Designated UST Operator' who lies passed the California UST System Operator Exam administered by the International Code Council <br />490-70. <br />(ICC). The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems annually, and within 30 <br />days of hire- This training will include, but is not limited to, the following: <br />Y Operation of the UST systems in a manner consistent with the facility's best management practices. <br />Y The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br />➢ The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br />A Nanhe(s) of contact person(s) ror enhergencies and monitoring alarms. <br />X. COMMENTS/ADDITIONAL INFORMATION <br />Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. <br />490-71. <br />The overfill prevention is a flapper valve set to shut off at 95% <br />XI. PERSONNEL RESPONSIBILITIES <br />The UST O%vncr/Operator is responsible for ensuring that: 1.) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment <br />covered <br />_this plan occurs; 2.) all conditions that indicate a possible release are investigated; and 3.) all monitoring records are maintained properly. <br />_b ..._...._ <br />_... - — - -- <br />THE FOLLOWING PERSON(S) ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTFNANCE: <br />NAME: Amanda Appelt 490-72 TITLE: Environmental Manager <br />440-7 <br />NAME: Matt Walling 490.74. TITLE: Compliance Technician <br />494-75, <br />The Designated UST Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br />Conditions that (heed follow-up action. <br />XII. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided hereht is true and accurate to the best of my tutowledge. <br />AI'PLlG\N'1' SiGNrll'URE <br />DATE: <br />490.77. <br />511612012 <br />REPRESENTING: N t. Tank Owner atot 1] 2. Facilit Gttmer 0 erator 3. , t sized R rcscntatim of 6m7w 491-76, <br />APPLICANT NAME (print): 490-78. <br />APPLICANTTITLE: <br />490-79. <br />Amanda Appelt <br />Environmental Manager <br />UPCF UST -D (12/2007) - 3/4 whviv.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.