• 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 7 <br />OFFICIAL INSPECTION REPORT <br />Date: 03/25/13 <br />Facility Address: Arco Mossdale 444 West Mossdale Rd, Lathrop <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />204. The designated operator failed to document all the alarms responses from the attached alarm <br />history on the August 2012 designated operator monthly inspection report and failed to check that they <br />were responded to appropriately. The missing alarm response include: August 08, 2012. Designated <br />Operator Karen Arnaiz had a alarm history print out dated August 7, 2012. The monthly report was dated <br />August 9, 2012. During the monthly inspection, the designated operator shall review the alarm history for <br />the previous month, check that each alarm was documented and responded to appropriately, and attach <br />a copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />204. The designated operator failed to document all the alarms responses from the attached alarm <br />history on the February and March 2013 designated operator monthly inspection report and failed to <br />check that they were responded to appropriately. The alarm history printout from the Veeder-Root <br />monitoring panel states "Set up data warning June 6, 2008 @ 8:02AM" for all sensors L1 -L10 for both <br />months. It is unclear what happened to the monitoring panel. During today's annual compliance testing, <br />the alarm history report for all sensors L1 -L10 states "Set up data warning March 7, 2013 @ 5:05PM". <br />During the monthly inspection, the designated operator shall review the alarm history for the previous <br />month, check that each alarm was documented and responded to appropriately, and attach a copy of <br />the alarm history with documentation taken in response to any alarms to the monthly report. Ensure that <br />designated operators performing monthly inspections at this facility are including all of the required <br />information on the reports. Submit an explanation for the cause of the Set up data warning along with <br />any work orders and how the Veeder-Root monitoring panel restored its programing. <br />204. The designated operator failed to check and note the correct test dates for the secondary <br />containment testing/ SB -989 on the designated operator monthly inspection reports from November <br />2010 to July 2012 (20 months). No date was documented and the designated operator check marked <br />'NA'. During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. It appears that the designated operator drop off the reports to the <br />site but no facility employees are reviewing the documents. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: <br />Title: <br />Thuy Tran (209) 468-8257 <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />