My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:35:02 AM
Creation date
6/3/2020 9:51:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 19 10 09:38a Reliable Petroleum <br />ill <br />Vmi <br />209;L45-8953 P.9 <br />4P <br />Vaporless Manufacturing, Inc. <br />Quality Petroleum Equipment <br />Solutions for Over 20 Years <br />Adjustment of VM1 Leak Detector <br />Certain Piping 00ad-Itions may affect the ability of any leak detector to rind a leak. They include <br />high head pressures and high bleed -backs. High bleed -back may occur due to dips in the lines, <br />stubbing for future dispensers, long pipe runs, and extremely flexible pipe. <br />Bleed -back can be interpreted as energy coming back on the leak detector and trying to force <br />the leak detector open. When a leak detector initially is installed and the fine pressure is zero <br />psi, the leak detector is in the reset position. When the pump starts, the leak detector allows <br />approximately 1-5 gallon per minute to pass through. In this position, the line is being filled with <br />product and the pressure in the line is slowly rising. <br />With the line filled with product, the pump still running, the line starts to expand as a balloon <br />might. The expansion of the line is creating energy that is being forced back onto the leak <br />detector piston. <br />Naturally, steel pipe has less expansion than fiberglass pipe, and much less expansion than <br />flexible pipe. <br />Air pockets in the line also raise the bleed -back level, so every effort should be made to <br />eliminate those air pockets by purging the line. <br />If a VMI leak detector fails to find a 3 GPH leak, the leak detector is not staying at the leak <br />sense position, but Instead is going through to full flow. <br />If, when testing the leak detector, the pressure gauge shows a starting pressure of 0 psi and <br />continues to pump operating pressure without hesitating at leak search pressure, the piston <br />assembly may not have completely reset. If this occurs 2 times in a row; you should (1) turn the <br />purnp off, (2) bleed the line pressure to 0 psi, (3) remove the vent line, (4) push the piston <br />assembly down. Turn the pump on and re -test the leak detector to assure it finds a leak. <br />Perform at least 2 additions! tests to ensure the leak detector is resetting on its own. <br />If, when testing the leak detector, it hesitates at leak search pressure but does not hold in leak <br />search position, an adjustment to the piston assembly may be made. The purpose is to make <br />the leak detector more sensitive to a leak. <br />To adjust the leak detector first remove the vent line and fitting from the top of the 99 LD -2000 <br />or LD -2200 leak detector (99 LD -3000 remove the cap). You will now be looking at the top of <br />the piston assembly. <br />VaPorless Nlanufacturinz, Inc. <br />9700 last Long !Mesa Drive, Prescott Valley, Arizona 863t4 <br />8001-367-0285 928-775 6191 Fax: 928-775-5309 <br />Email: vfniCaMporlesscom WeWte: www.vagQrigg.corn <br />