Laserfiche WebLink
MONITC#ING SYSTEM CERTIFWATION <br />MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC <br />CERTIFICATION 1 TEST DATE: August 10, 2006 <br />A1. FACILITY <br />A2. OWNER <br />Name Quik Stop Market # 76 <br />Name Quik Stop Markets, Inc. <br />Address 1030 S. Olive Avenue, Stockton, CA 95215 <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />Contact Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 304 E Weber Avenue, 3rd Floor, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified July 28, 2006 <br />Lic # 617238 A, B, Haz <br />Inspector Raymond Von Flue <br />Contact Richard Walton <br />Phone # 209-468-9847 <br />Phone # 916-825-3203 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />131: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 91 <br />■ In-Tank Gauging Probe Model: <br />0847390-109 ■ In-Tank Gauging Probe Model: 0847390-109 <br />■ Annular Space or Vault Sensor Model: <br />0794380-303 ■ Annular Space or Vault Sensor Model: 0794380-303 <br />■ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />0794380-208 ■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: <br />FE Petro MLD ■ Mechanical Line Leak Detector Model: FE Petro MLD <br />❑ Electronic Line Leak Detector Model <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High-Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Tank Overfill / High-Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): <br />Tank #4 (Product): <br />❑ In-Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ In-Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />- - ❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />- ❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model <br />❑ Tank Overfill / High-Level Sensor Model: <br />❑ Tank Overfill / High-Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />— <br />❑ Other (specify equipment in Section E) Model: <br />132: DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />1 Dispenser # : 3-4 <br />❑ Dispenser Containment Sensor(s) Model: <br />_ ❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />I Dispenser # <br />ElDis Dispenser Containment Sensor(s) P (s) Mode <br />❑ Shear Valves- <br />— ❑ Dispenser Containment Sensor(s) Model: <br />ElShear Valves <br />I <br />❑ Dispenser Containment Float(s) and Chain(s) <br />�I <br />El Dispenser Containment Float(s) and Chaln(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable <br />of generating such reports, 1 have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />WALTON <br />Signature: �J�CX <br />ENGINEERING, INC. <br />Technician / Cert M Bruce N. Stewart / A31131 <br />5249892-UT Date: August 10, 2006 <br />c zoos wa¢on engineenng, Inc. <br />