Laserfiche WebLink
MONITG#ING SYSTEM CERTIFOATION <br />CERTIFICATION / TEST DATE: August 10, 2006 <br />Al. FACILITY <br />A2. OWNER <br />Name Quik Stop Market # 76 <br />Name Quik Stop Markets, Inc. <br />Address 1030 S. Olive Avenue, Stockton, CA 95215 <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />Contact Michael Karvelot <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Gilbarco EMC <br />Software Version Installed: 16.04 <br />Complete the following checklist: <br />■ Yes ❑ No* Is the audible alarm operational? <br />■ Yes ❑ No* Is the visual alarm operational? _ - — <br />■ Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />■ N/A operational? <br />— <br />— — — — — — — — <br />Yes ❑ No* For -pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sump/Trench sensors; ❑ Dispenser Containment Sensors. <br />■ Yes ❑ No* Did you confirm positive shut -down due to leaks and sensor failure/disconnection? <br />❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />■ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? <br />❑ Yes * ■ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />~ ■ Yes * ❑ No Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) ❑ Product; ■ Water. If yes, describe causes in Section E, below. <br />❑ Yes ■ . No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Found minor condensation in both STP sumps. Found 2 gallons of water in 87 fill sump. <br />Found 42.5 gallons of water in 91 fill sump. <br />zeue wanon engmeenng, mc. <br />Page 2 of 3 <br />