Laserfiche WebLink
SAN JOAQUIN COUNTY 10 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> s 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si-gov.orq/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> AASF # 2 Aug 4, 2010 <br /> Facility address: UST#/ 6 <br /> 2000 Stimson Road, Stockton Product ,i FUEL - <br /> Facility contact Title: Phone: <br /> MSG. Antonio Pica System Supervisor 209 983 5331 - - - <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> ❑ Mechanical M1-RDetect❑W-Both <br /> Veeder Root TLS 350 Pressurized®Suction❑Gravity Audible/visual M2-RPrev <br /> Inspection type: Designated operator. ICC exp.date: <br /> ©Routine ®Monitoring Certification ❑Installation ❑other Hector Galindo 1/7/11 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Hector Galindo 6/23/11 Veeder Root - A23915 <br /> VIOLATIONS R <br /> # Code Section HSC---CA Health&Safe Code;CCR=CA Code of Regulations;V=Violation;RV=Re at Violation V V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711(b)&(c) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 6 CCR 2712(1) Monitoring and/or response plan is not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6% (M7) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs,linings,and upgrades for the life of the tank. Monitoring records include:(1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-Janus 1, 1984)not performed (M1) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST/piping (11117) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M7) <br /> containment <br /> 13 CCR 2636(0(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M7) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 17 CCR 2636(f)(2) Line leak detecto s)not installed or failed to detect a3-gallon per hour leak at 10 psi (M7) <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum capacity of five gallons,or failed to (0112) <br /> provide a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (11112) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (11112) <br /> 21 HSC 25291(e) Water in 21 containment not removed,analyzed&propedy disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (M7) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD inspector Recei b: Title: <br /> �M t <br /> EHD 23-02-002 REV 04/08/10 Pag 1 UST OFFIC L INSPECTION REPORT <br />