Laserfiche WebLink
4 . SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> V 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.orci/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> AASF # 2 Aug 4, 2010 <br /> # Code Section VIOONS R <br /> HSC=CA Health&Safe Code;CCR=CAC dle of Regulations;V=Violation;RV=Repeat Violation V V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-1)spill containers, <br /> 23c CCR 2715(c),(d), UDCs,and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6) X <br /> (e) employee training no verified;(d)(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed;(2)not current for at least one employee <br /> on site;(3)log no kept <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair,replacement,calibration,or certification;(f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified,repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed (NII) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line t' htness test not performed if positive shutdown or fail safe not present (NII) <br /> 28 CCR 2661(0 Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (111I1) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (NII) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(a)(9) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) I Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 J CCR 2636 f)(6) Eme encgenerator monitoring system no checked daily or log not kept (Mi) <br /> 41 1 HSC 25281.5(b)(3) I Unburied fuel piping not visually inspected at least monthly or log not kept (NII) <br /> VPH Systems HSC 25290.2 installed between 07/01/03 and 06/30/04 HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and(d)for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Prima containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) Primary <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the <br /> HSC 252902(d) entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space <br /> of the UST system not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2) <br /> 48 HSC 252902(i) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> EHD inspector. Phone. UIC <br /> 209 468-3439 Seotic system: <br /> ❑Serves 20 people/day <br /> Received by ride. ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> ` ❑Dry wells/French Drains <br /> D 21-02-002 REV 04/0 10 Page 2 UST OFFICIAL INSPECTION REPORT <br />