My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1985-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2024 4:16:30 PM
Creation date
6/3/2020 9:51:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1998
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1985-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
573
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Imay"* Z41 <br />Monitoring alternative 9 is part of the proposed amendments to <br />the Underground Storage Tank Regulations. Assuming these <br />regulations are adopted, this alternative would be applicable. <br />Implementation of this monitoring alternative will require Daily <br />Inventory Reconciliation, Rate of Volume Change testing, Annual <br />Tank Integrity testing, and Pipeline Leak detection. If this <br />monitoring alternative is chosen, implementation should be <br />carried out as follows: <br />1) Perform the initial tank integrity test/tests to confirm that <br />the tank/tanks do/does not leak at the time of implementation <br />of the monitoring alternative. Integrity testing must be <br />done within one year prior to implementation of the <br />monitoring alternative. Based on information obtained from <br />facility personnel all/the tanks/tank at this facility have <br />passed an integrity test within the last year. <br />2) Daily Inventory Reconciliation shall be accomplished using a <br />tank level monitor (automated liquid level monitoring <br />equipment). This tank level monitor shall be capable of <br />monitoring the volume of fuel in the tank and performing the <br />required rate of volume change testing. The tank level <br />monitor shall meet the minimum requirements as specified in <br />Section 2641, Subsection C -9(D and E) of the proposed <br />amendments to the Underground Storage Tank Regulations <br />Allowable daily inventory variation and the frequency of rate <br />of volume change testing shall be dependent upon which <br />monitoring schedule is chosen from Section 2641 Table 4.3. <br />Further refinement of the specifications required for <br />complying with this monitoring alternative are outlined in <br />Section 2641 Monitor Alternative 9. Specifications <br />regarding three types of tank level monitors, each of which <br />should be suitable for use at this facility, are attached at <br />the end of this package. <br />3 Implementation of this monitoring alternative will require <br />annual calibration of flow meters by the State of California <br />Bureau of Weights and Measures. <br />4) Pipeline leak detection requirements can be accomplished by <br />visual inspection since the method of product delivery is by <br />suction pump. Monitoring shall be as described in Appendix <br />II of the Underground Storage Tank Regulations. <br />5) Tank integrity testing to determine that total product loss <br />from the tank does not exceed 0.05 gallons per hour, shall be <br />performed every three years. Integrity testing shall be <br />carried out as specified in Section 2643 of the Underground <br />Storage Tank Regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.