Laserfiche WebLink
CAFE -EN <br />SUBJECT: Daily Inventory Reconciliation - Letter of Instruction (LOJ <br />to Monday. •r variation must •• exceed the allowable variation (Table <br />• (.0015) times the metered throughput (Column 7). Monthly is <br />defined as thirty sequential days, i.e. 31 July to 30 August. <br />5. Table 2 (Enclosure 1) is provided as an example for filling out the <br />Monthly Inventory Review Sheet. <br />6. The Underground Tank Regulations stipulate required actions when the above <br />listed allowable variations are exceeded. The tank operator or his designated <br />replacement will: <br />a. • the Environmental Planner, OTAG, at (9 16) 973-3340, or Autovon <br />466-3340, during duty hours; or at home, (916) 726-6943 at other times within <br />24 hours • the daily reconciliation figure exceeding the allowance. <br />b. Review the inventory records within two hours to determine if a mathe- <br />matical error caused the gain or loss to exceed the allowable limit. <br />c. Notify the local • agency as soon as possible but within 12 <br />hours. The agency will appoint a qualified person to review the inventory <br />reconciliation records including past readings. This review, to be concluded <br />within 24 hours of the triggering reconciliation, will include a new inventory <br />reconciliation reading to be taken at least eight hours after the triggering <br />reconciliation. <br />e. The Environmental Planner will inate emergency contracting action <br />for isolating and hydrostatic testing of all associated piping within 72 hour <br />and of the tank within 24 hours after completion of the piping test. I <br />7. The local agency will require a quarterly statement, under penalty of <br />perjury, to be filed with them stating that all reconciliation data was withiT <br />allowable limits, or identifying the dates that the amounts exceeded the limit <br />and actions taken to correct the situation. Contact should be made with the <br />local agency to determine quarterly statement format. <br />8. Monthly inventory review sheets will be retained for a minimum of one year <br />at the facility and then forwarded to the Environmental Planner, Facilities <br />Engineering Directorate for permanent record. These sheets will be made <br />available for inspection to any representative of the local agency or Regional <br />Water Quality Control Board upon request. <br />9. The Environmental Planner will be notified immediately if the pipeline or <br />tank integrity is in doubt, or if problems develop in the dispensing or storage <br />0 <br />