OPW 61SO-1000 and <br />61SO-100C Grooved Tube <br />The OPW 6150-1000 and <br />6150-100C Overfill Prevention <br />Valves feature a grooved tube design <br />for use in two-point applications with <br />tank gauging probes. The 61 SO -100C <br />is CARB approved. <br />These valves have a slotted section <br />that runs through both the tube and the <br />valve body to allow the installation of <br />most manufacturer's gauging systems - <br />with only a negligible effect on product <br />delivery time. <br />All OPW 61SO series valves are fur- <br />nished with complete instructions and <br />all of the necessary hardware for field <br />or shop assembly. <br />For complete assembly and installa- <br />tion instructions, refer to C -3557 -PA <br />(OPW 61SO and 61SOM) or C -3634 - <br />PA (OPW 61SOC) or C -3687 -PA <br />(OPW 61 SOP) or C -3792-M (OPW <br />61SOR). <br />Materials <br />Valve body: cast aluminum <br />Float: nitrile rubber, closed cell foam <br />Valve: aluminum <br />Seals: viton <br />Upper & lower Drop Tube: aluminum <br />Plastic parts: Acetal <br />Hardware: Stainless Steel <br />Replacement Parts <br />Part No. Description <br />61 SOK-0001 Float Kit <br />C03899M Two point inlet tube <br />C03632M Coaxial inlet tube <br />Important <br />In order to prevent product spillage <br />from the Underground Storage Tank <br />(UST), properly maintained delivery <br />equipment and a proper connection at <br />the tight fill adaptor are essential. <br />Delivery personnel should be managed <br />and trained to inspect delivery elbows <br />and hoses for damaged and missing <br />parts. They should always make certain <br />there is a positive connection between <br />the adaptor and elbow. If delivery <br />equipment is not properly maintained, <br />or the elbow is not securely coupled to <br />the adaptor - a serious spill may result <br />when the OPW 61 SO closes - causing <br />a hazard, and environmental contamina- <br />tion. <br />Note: The OPW 6150 Overfill <br />Prevention Valve is not to be used in <br />pumping applications. The 61SO is <br />designed only for tight fill, gravity <br />drop applications. <br />Information <br />For additional useful information on <br />the specification, assembly, installation <br />and use of the OPW 61SO, refer to <br />Technical Bulletin TB -6150. <br />OPW 61 SO Overfill Prevention <br />Valves are covered under the following <br />patent: 4,986,320. Re 33,555 and <br />Canadian patent 1,287,546. Other <br />patents pending. <br />IMPORTANT. OPW products should be used in <br />compliance with applicable federal, state and local laws <br />and regulations. Product selection should be based on <br />physical specifications and limitations and compatibility <br />with the environment and materials to be handled. <br />OPW MAKES NO WARRANTY OF FITNESS <br />FOR A PARTICULAR USE. All illustrations and <br />specifications in this literature are based on the latest <br />product information available at the time of publication. <br />OPW reserves the right to make changes at any time in <br />prices, materials, specifications and models and to <br />discontinue models without notice or obligation. <br />EP 19.0 <br />