Laserfiche WebLink
ELECTRICAL WORK <br />Section 16050 - Page 2 is <br />B. Rigid Steel Conduit: <br />1. Standard weight, threaded, zinc coated on outside by hot dipping, <br />sherardizing or metallizing process, with protective finish coating on <br />outside and inside. <br />2. Fittings: Threaded type, steel or malleable iron; set screw type or <br />threadless type, not acceptable. <br />C. Rigid PVC Conduit. <br />1. Schedule 40 rigid polyvinyl chloride electrical conduit, listed by UL for <br />direct underground burial, manufactured from high impact, nonconducting, <br />selfextinguishing material. <br />2. Couplings, Adapters, Expansion Fittings: Conform to same requirements <br />as rigid PVC conduit. Use solvent cement for all PVC joints, as recom- <br />mended by conduit manufacturer. <br />3. Bends: Factory made rigid steel conduit bends; PVC conduit bends, not <br />acceptable. <br />D. Protective Coating: Metallic raceways in direct contact with earth or fill <br />of any type, shall be zinc coated rigid steel conduit with corrosion resisting <br />protective coating, consisting of spirally wrapped pressure sensitive tape <br />with protective overwrap, or factory applied coating. <br />1. Tape: Polyethylene or PVC, min thickness of backing material 0.010", min <br />dielectric strength of 10,000 volts, Johns Manville #E-12 and #VID-10, <br />Chase #750, Polyken #900, 3M Co., #50, Plymouth #100, or equal. <br />2. Protective Overwrap: Either 15 lb tar or asphalt saturated felt secured <br />with tape; or asphalt laminated kraft paper reinforced in both directions, <br />American Sisal Kraft 4207, Chase X6770, or equal. <br />3. Application: Clean conduit before applying tape, using totally volatile <br />solvent so as to leave no oil. Tape and overwrap to be machine applied <br />using 1/2" min lap. Apply wraps uniformly and tightly, free of voids <br />and wrinkles. <br />Where total length of conduit for entire project does not exceed 501, <br />tape and overwrap may be hand applied. <br />4. Factory Applied Coating: PVC seamless jacket, min thickness 0.020", <br />firmly bonded to galvanized surface of rigid steel conduit, Occidental <br />Coating Co., "OCCAL-20", Plastic Applicators "KorKap", Pittsburgh <br />Standard Conduit Co "PlastiBond", or equal. Where standard 90° and 45° <br />bends are required use PVC jacketed factory made bends. Where field <br />bends are required, use standard bender of next larger size, and protect <br />section of conduit to be bent with kraft paper wrap. <br />5. Field Joints. <br />a. For Wrapped Conduit: Cover field joints and bends with 2 layers of <br />tape and one layer of overwrap, applied with 1/2" min lap and extend- <br />ing at least 6" over adjacent covering. Tape and overwrap as <br />specified above, except tape 2" wide max. Tape overwrap in place. <br />b. For Factory Coated Conduit: Use factory coated, rigid steel fittings <br />with overlapping PVC sleeves, 0.040" min thickness. Sleeves shall <br />extend beyond end of fitting min distance equal to nominal dia of <br />conduit, and shall fit tightly over conduit coating to form a water- <br />tight joint. <br />021387:cw MAR 702 <br />.. <br />