Laserfiche WebLink
SAN J UAQUI N LOCA- . HEALTH DI STE2I CT <br />MININUM VERIFICATION <br />Total Petroleum Hydrocarbon, Gasoline <br />LABORATORY <br />ANALY615 <br />CL HC[TEL <br />(8010)D� <br />(8240) <br />EDB METALS <br />H S) (ICP- <br />AES) <br />—. X <br />PCB <br />(8270) <br />TANK CONTENTS TPH-G <br />Waste Product GC -FID <br />ori.=_ .............. ( 5030)(3540) <br />TPH-D <br />GC -FID <br />TEPH <br />(3550) <br />BTX&E <br />(8020) <br />LEADEDGASOLINEX <br />UNL - GASOLINE X <br />DIESEL <br />X <br />X <br />X <br />X <br />GC FID <br />Gas Chromatography Flame Ionization Detector <br />ICP -AES OR AA <br />Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br />Absorption Spectrometry <br />Method 5030 <br />Purge and Trap Sample Preparation <br />Method 3550 <br />Sonication Sample Preparation <br />Method 3540 <br />TUNKNOWN FUEL X <br />QA/QC <br />X <br />X <br />positive detection of benzene; benzene -free solvents are to be used. <br />X <br />X <br />samples or once hydrocarbons have been characterized and <br />proper QA/QC is followed. <br />OIL _- <br />CHLOR. SOLVENTS <br />For Drinking Water <br />X <br />X <br />X <br />X <br />the QA/QC is better. <br />NONCHLOR . SOLVTS <br />X <br />WASTE/USED OIL <br />X <br />- X _ <br />X <br />X <br />X <br />MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY <br />The following listing of laboratory analyses abbreviations is provided as a guide so that <br />terminology used will be more familiar. All analyses methods are designated EPA methods as <br />described in EPA SW 846, Third Edition. Those methods not found in SW 846, are <br />specifically noted. <br />TPH G <br />Total Petroleum Hydrocarbon, Gasoline <br />TPH D <br />Total Petroleum Hydrocarbon, Diesel <br />TEPH <br />Total Extractable Petroleum Hydrocarbon (8015 <br />BTX & E (8020) <br />Benzene, Toluene, Xylene & Ethyl Benzene (802 ) <br />CL HC 8010 OR 8240 <br />Chlorinated Hydrocarbon 8010 or 8240 <br />TEL (DOHS-LUFT) <br />Tetraethyl Lead (DOHS-LUFT) <br />EDB (DOHS -AB 1803) <br />Ethylene dibromide (DOHS -AB 1803) <br />GC FID <br />Gas Chromatography Flame Ionization Detector <br />ICP -AES OR AA <br />Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br />Absorption Spectrometry <br />Method 5030 <br />Purge and Trap Sample Preparation <br />Method 3550 <br />Sonication Sample Preparation <br />Method 3540 <br />Soxhlet Sample Preparation <br />QA/QC <br />Quality Assurance/Quality Control <br />Notes: To avoid false <br />positive detection of benzene; benzene -free solvents are to be used. <br />Fused capillar columns are preferred to packed columns; a packed column may be used as a <br />"first "dirty" He <br />cut" with <br />samples or once hydrocarbons have been characterized and <br />proper QA/QC is followed. <br />For Drinking Water <br />Sources EPA recommends that the 500 series for volatile <br />the lower <br />organics be used in preference <br />to 600 series because the detection limits are and <br />the QA/QC is better. <br />EH 23 048 12/88 <br />