My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:40:58 PM
Creation date
6/3/2020 9:52:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Waterloo Food & Fuel Facility 3032 E. Waterloo Rd., Stockton Inspection Jul 18, 2012 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> x, <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M7) <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1, CLASS II, or MINOR-Notice to Comply) <br /> This is an annual Monitoring Certification inspection of the UST facility at the referenced address. The <br /> following are Class I violations: 108,109,110,111,112,118,119,120,301,302, 303, 304,305,311,317 <br /> 108. Secondary containment testing was last performed on 8/18/2008 and was due by 8/31/2011. <br /> Testing has not been completed and is 11 months past due. Secondary containment testing is required <br /> once every 36 months. Immediately schedule this test and provide 48 hours notification to the EHD. <br /> 109, 110, & 111. Annual leak detector testing, spill container testing, and monitoring system certification <br /> (including annual line test since there positive shutdown for the 91-octane and diesel UST systems had <br /> not been verified), were last performed on June 29, 2011 and was due by June 30, 2012. These tests <br /> are required once every 12 months. Annual leak detector testing, spill container testing, and monitoring <br /> system certification were conducted during this inspection today. <br /> 118. The 87 and 91-octane USTs, and the diesel UST are currently not being monitored by the existing <br /> INCON monitoring system as described on the monitoring plan. An amended operational permit was not <br /> obtained when the monitoring system was changed. The UST owner or operator shall notify the EHD <br /> within 30 days of any changes in the operation of the UST system. Immediately submit a permit <br /> application to the EHD for this change. An "Amended Permit Fee" applies. <br /> 119,120 & 317. The 91-octane and the diesel USTs have been found to be illegally abandoned since <br /> the two USTs were Red Tagged on July 20, 2011, and a Notice to Abate dated September 22, 2011 <br /> were served to you for illegal abandonment of the two UST systems. No person shall abandon an UST <br /> system without complying with the requirements of HSC 25298. Immediately obtain a permit from the <br /> EHD to remove this UST system, or a permit to temporarily close this UST system only if the USTs are <br /> to be reused within one year of closure. A "Failure to Obtain a Permit" penalty applies. <br /> 301. The 87 and 91-octane UST system, and the diesel UST systems are currently not being monitored <br /> to prevent unauthorized release. The underground storage tank system shall be operated to prevent <br /> unauthorized releases. Immediately begin operating UST system that will prevent unauthorized <br /> releases. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector:. Received Title: <br /> EHD 2402 RX 09/1 ( age 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.