Laserfiche WebLink
71IF141-FIED PROGRAM CONSOLIDATED F07!71 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Page 2 of 2) <br /> (Check all <br /> _ja <br /> VI. UNDER DISPENSER CONTAINMENT (UDC)MONITORING �l <br /> that apply) <br /> UDC MONITORING IS PERFORMED USING THE FOLLOW4G METHOD(S) <br /> Z 1.CONTINUOUS ELECTRONIC MONITORING Fl 2.FLOAT AND CHA;N ASSEMBLY El 3.ELECTRONIC STAND-ALONE 490-54a. <br /> ❑ 4.NO DISPENSERS ❑ 99.OTHER(Specify) 490-54b. <br /> LEAK MONITOR MANUFACTURER:INCON 490-55. MODEL#:TS1 001 490-56. <br /> LEAK SENSOR MANUFACTURER:INCON 490-57. MODEL#(s):TSP-ULS 490-58. <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. El a.YES [I b.No 490-59. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. 0 a.YES E] b.No 491-60, <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. 0 a.YES El b.NO 490-61. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPE.qSER. 0 a.YES M b.No 490-62. <br /> ...................................................I.......................I..........­........................................................................­­............................ ...........................................................................................................................................................................................................................................................................................................................................-...................... <br /> UDC CONSTRUCTION IS: 1.SINGLE WALL [:1 2.DOUBLE WALL 490-63. <br /> IF DOUBLE WALL: 490-64a. <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: 13 a.LIQUID El b.PRESSURE E3 c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. F-1 a.YES [1 b.NO 490-64b. <br /> VII. PERIODIC SYSTEM TESTING <br /> El 1.ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65. <br /> LEAK DETECTION(ELD)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.[23 CCR§2644.11 <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66. <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67. <br /> VIII. RECORD KEEPING <br /> The following monitoring/maintenance records are kept for this facility: 490-68. <br /> a.ALARM LOGS [:1 b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) El e.TANK GAUGING RESULTS(and supporting documentation records) <br /> ❑ f ATG TESTING RESULTS(and supporting documentation records) [:1 g.CORROSION PROTECTION 60-DAY LOGS <br /> h.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX. TRAINING <br /> S Personnel with UST monitoring responsibilities are familiar with all of the followir-documents relevant to their job duties: 490-69a. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITYL (Check all that apply; <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490-69b. <br /> OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(kequired) 490-69c. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69e. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND 490-69f <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490-69& <br /> ❑ OTHER(Specify): 490-69h,490-69i. <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council 490-70 <br /> (ICC). The "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> > The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> > The facility employee's role with regard to spills and overfips as specified in the facility's UST Response Plan. <br /> > Name(s)of contact person(s)for emergencies and monitoring alarms. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490-71, <br /> POSITIVE SHUTOFF FLAPPER SET AT 95% OF FUEL CAPACITY <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1.)the daily/routine UST monitoring activities and maintenance of LIST leak detection equipment covered <br /> by this plan occurs;2.)all conditions that indicate a possible release are investigated;and 3.)all monitoring records are maintained.�prqp y................................................ <br /> .........................................................................-............................................................................................................ ........ ..........T..... ..................... - - -................- ­­­­1 - -..................... <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE M,)NITORING AND EQUIPMENT MAINTENANCE: <br /> NAME: WATERLOO FOOD&FUEL 490-72 TITLE:FACILITY OWNER 490-73. <br /> NAME: 490-74 TITLE: 490-75. <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: I certifnthat the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE DATE: 490-77. <br /> 7/18/2012 <br /> REPRESENTING:0 1.Tank Owner/Operator Fa ifity Cwner/Operator 0 3.Authorized Representative of Owner 490-76. <br /> APPLICANT NAME(print): 490-78. APPLICANT TITLE: 490-79. <br /> PAUL SINGH MANAGER <br /> UPCF UST-D(12/2007)-3/4 www.unidocs.org <br />