Mon0cri.ng System Certification <br />a` Site Address:01 ` Date oF'I'esting/Servicing: <br />d- F. In -Tank Gauging / SIR Equipment: Teck this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Comnlete the following checklist: <br />❑ Yes <br />❑ <br />No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />❑ Yes <br />❑ <br />No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />❑ Yes <br />❑ <br />No* <br />Was accuracy of system product level readings tested? <br />❑ Yes <br />❑ <br />No* <br />Was accuracy of system water level readings tested? <br />0 Yes <br />❑ <br />"No* <br />Were all probes reinstalled properly? <br />0 Yes <br />❑ <br />No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />to me aecnon n, oeiow, uescrtoe now anu when these ucliciencies were or will be corrected. <br />G. Line Leak Detectors (LLD): ❑ Check this box if LLDs are not installed. <br />Comntete the following checklist: <br />Yes <br />❑ No* <br />❑ N/A <br />For equipment start-up or annual equipment cetfication, was a leak simulated to verify LLD performance? <br />(Check all that apply) Simulated leak rate: 0 3 g.p.h.; ❑ 0.1 g.p.h ; ❑ 0.2 g.p.h. <br />C3 Y� <br />❑ No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />Ye . <br />❑ No* <br />Was the testing apparatus properly calibrated? <br />Yes <br />❑ No* <br />❑ N/A <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />❑ Yes <br />�❑ Ngo* <br />U_ N/A <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />❑ Yes <br />❑ No* <br />�A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br />or disconnected? <br />❑ Yes <br />❑ No*-- <br />N/A I <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system <br />malfunctions or fails a test? <br />❑ Yes <br />E❑ NN** <br />C - N/A <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />Ef Yes <br />❑ No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />,f7 uec occuvu n, ueevw, uescrloe now anu wnen tnese uenciencies were or will be corrected. <br />H. Comments: <br />