Figure 31. Probe Riser Cap Modification. <br />If a kit has not been ordered, perform the following: <br />.114 WARNING: DO NOT PERFORM DRILLING, FILING, <br />GRINDING AND TAPPING PROCEDURES IN A HA- <br />ZARDOUS AREA. DRILLING, FILING, GRINDING <br />AND TAPPING CAN CAUSE SPARKS AND IGNITE <br />VOLATILE FUMES AND LIQUIDS FOUND IN A <br />CLASS I, GROUP D HAZARDOUS LOCATION. FAIL- <br />URE TO COMPLY COULD RESULT IN DEATH, <br />SERIOUS PERSONAL INJURY, PROPERTY LOSS <br />AND EQUIPMENT DAMAGE. <br />1. Use a standard 4" tank locking cap, "Evertite" or equiva- <br />lent, with standard ring adaptor (without lugs). <br />2. Check for lugs on the ring adaptor. If present, these lugs <br />will interfere with the float installation and the adaptor <br />ring must be replaced or modified (see Figure 32, "Ring <br />Adaptor Modification"). To modify the ring, first remove it <br />from the HAZARDOUS area, then file or grind off the lugs. <br />Once the floats fit, install adaptor on riser pipe. <br />6 REMOVE <br />3.875 <br />MINIMUM <br />Figure 32. Ring Adaptor Modification. <br />3. Drill and tap the cap for a 3/8 x 18 NPT cord grip thread <br />(see Figure 31, "Probe Riser Cap Modification"). <br />4. Install a water -tight cable bushing in the 3/8" threaded <br />hole in the top of the cap. Use an appropriate thread <br />sealant to ensure water -tightness. Also install a water- <br />tight cable bushing in the probe junction box in a similar <br />manner. <br />Site Preparation and Installation Instructions <br />EMC UST Monitoring System <br />h1 � <br />Install each probe as follows (see Figure 33, "Magnetostrictive <br />Probe Installation Requirements"): <br />a. MINIMUM DIA <br />MANHOLE <br />- L <br />OF AC<_' EAar.. <br />2 CORD GRIP SEALS <br />PER °61 <br />SUPPLIED WITH PROBE <br />\ <br />STRAIN\ <br />'.YEN THERPPCOF <br />REL. EF <br />a CT�.ON BOX WITH <br />CHAIN <br />I Z INCH NPT THDE <br />.16 CUeiC INCH <br />MINIMUM. <br />EPDXY SEAL <br />"I PERNF FA <br />SPEC <br />8" MIN <br />SEE <br />PE CABLE <br />-NOTE <br />SUPPLIED WITH <br />SLP <br />RISER DIMENSION <br />PROBE <br />SHOULD 1B" <br />FTO <br />TO <br />THE BOTRISER C OF <br />THE RISER CAP <br />A vlvE <br />SCHEDULE °0 <br />SCHEDULE <br />MAGNETOSTRICTIVE <br />TANK <br />PROBE <br />Note: Increase this minimum dimension if the tank <br />diameter does not match the probe length. <br />(Example: A 7'6" dia. tank will use an 8' <br />probe. The extra probe height will be lodged <br />in the riser pipe, which must be 6" longer <br />than the minimum in order to provide room.) <br />Figure 33. Magnetostrictive Probe Installation Requirements. <br />1 WARNING: TO AVOID ELECTRICAL SHOCK <br />WHICH COULD KILL YOU, BE SURE AC POWER TO <br />THE MONITOR IS OFF DURING INSTALLATION. <br />1. Turn OFF power to the EMC system. <br />2. Make sure any liquid other than the product to be <br />dispensed has been pumped out of the tank. <br />3. Be sure there is no sludge in the bottom of the tank. <br />Sludge can interfere with proper operation of the water <br />float. <br />CAUTION: HANDLE PROBES CAREFULLY! STRIKING <br />OR DROPPING PROBE WILL RESULT IN LOSS OF CAL - <br />16 AND COULD CAUSE PERMANENT <br />DAMAGE. <br />4. Attach the probe cable connector to the mating plug on <br />the top of the probe. Be sure the connector is attached <br />securely by hand tightening the locking ring on the probe <br />cable connector. <br />5. Hook the open end link of the strain relief chain to the <br />attachment point provided on the probe cable. Crimp the <br />link closed to prevent accidental detachment. <br />6. Place floats at bottom of probe before standing the probe <br />on end. <br />10 CAUTION: HANDLE PROBES CAREFULLY! STRIK- <br />ING OR DROPPING PROBE WILL RESULT IN LOSS <br />OF CALIBRATION AND COULD CAUSE PERMANENT <br />DAMAGE. <br />21 <br />