My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
!E(;LiVtD <br /> Appendix V1 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hftp://www.swrcb.ca.gov.�A�l <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use All Jurisdictions Within the State of California 0 <br /> Authority Cited.,Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California codiF6f-'' <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#99840 Bldg.No.: <br /> Site Address: 4344 E WATERLOO RD@ 99 City: STOCKTON Zip: 95215 <br /> Facility Contact Person: MANAGER Contact Phone No.: 209-931-2186 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 12/29/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment ins serviced: <br /> Tank ID: T1-SUPREME Tank ID: T2-REG UNLEAD <br /> W In-Tank Gauging Probe. Model: mag 8473 rwo in-Tank Gauging Probe. Model: mag 8473 <br /> W Annular space or Vault Sensor. Model: 409 F70 Annular space or Vault Sensor. Model: 409 <br /> P Piping Sump/Trench Sensor(s). Model: 208 W Piping Sump/Trench Sensor(s). Model: 208 <br /> r Fill Sump Sensor(s). Model: r— Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> rV Electronic Line Leak Detector. Model: Veeder Root PLLD rvO Electronic Line Leak Detector. Model: Veeder Root PLUD <br /> Tank Overfill/High-Level Sensor.Model: flapper rvo Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment type and model in Section E on PacieT_. r—Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> r In-Tank Gauging Probe. Model: r In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> r— Mechanical Line Leak Detector. Model: r— Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill if High-Level Sensor.Model: r—Tank Overfill/High-Level Sensor.Model: <br /> r Other(seecify equipment type and model in Section E on Page r—Other(specify equipment type and model in Section E on Facie 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> W Dispenser Containment Sensor(s).Model: 208 rV Dispenser Containment Sensor(s).Model: 208 <br /> P Shear Valve(s). rv-0 Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> r%O Dispenser Containment Sensor(s).Model: 208 rW Dispenser Containment Sensor(s).Model: 208 <br /> rV Shear Valve(s). R Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> rvO Dispenser Containment Sensor(s).Model: 208 ryO Dispenser Containment Sensor(s).Model: 208 <br /> R Shear Valve(s). P Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). I r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that apply).P System set- <br /> up P Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> Certification No.: 842815 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 12/29/2015 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.