My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br /> G -k E D <br /> JN I I 2io <br /> D.Results of Testing/Servicing <br /> Software Version Installed: 329.01 <br /> .,9 .�,"wry-.4r$R•,... <br /> Complete the following checklist: t"@P_-'� <br /> • Yes r No* Is the audible alarm operational? <br /> Yes ;: No* Is the visual alarm operational? <br /> • Yes r No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> s Yes r No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere wit <br /> heir proper <br /> o eration? <br /> Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> * N/A <br /> 170 Yes "; No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring <br /> stem detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check <br /> N/A all that applyJ7 Sump/Trench Sensors; '+'"Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection?de Yes; r No <br /> • Yes +` No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill <br /> prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If <br /> N/A o at what percent of tank capacity does the alarm trigger?% <br /> __ Yes* • No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E below. <br /> • Yes* * No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) <br /> Product Water.If yes,describe causes in Section E below. <br /> • Yes =` No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Yes „'; No* s all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E.Comments: <br /> Monitoring System Certification Page 2 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.