PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Opecel <br /> 8.FILL RISER CONTAINMENT SUMP TESTING �zo <br /> Facility is Not Equipped With Fill Riser Containment Sumps r DE <br /> Fill Riser Containment Sumps are present, but were Not Tested Zan— eu/4 <br /> V Vi <br /> Test Method Developed By: r-Sump Manufacturer F Industry Standard FProfessional Eng ._ <br /> F Other(Specify) ® - <br /> Test Method Used: Pressure F Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> ill Sump Fill S amp Fill Sump Fill Sump <br /> UE020U001 <br /> Sump Diameter: 40" <br /> Sump Depth: 46" <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: NA <br /> Height from Tank Top to Lowest 17" <br /> Electrical Penetration: <br /> Condition of sump prior to Good <br /> testing : <br /> Portion of Sump Tested: 2" above collar <br /> Sump Material: Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min. <br /> starting test: <br /> Test Start Time: 10:39 am 10:54 am <br /> Initial Reading(Rj): 3.8879 3.8879 <br /> Test End Time: 10:54 am 11:10 am <br /> Final Reading(RF): 3.8880 3.8878 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF'Rl): .0001 .0001 <br /> Pass/Fai I Threshold or Criteria: .002 .002 <br /> Test Result: F-'' Pass F Fail r Pass r Fail F Pass f Fail ' Pass Fail <br /> Is there a sensor in the sump? P Yes No Yes r No r Yes No r Yes No <br /> Does the sensor alarm when either p��°' g ]� <br /> product or water is detected? 1 Yes 1 No gr NA gf Yes 3 No r NA Ya g— No 3 NA r Yes gr No 3p NA <br /> Was sensor removed for testing? 3v' Y. r- No 1 NA 1 Yes F No r- NA r- Yes 3 No NA r- Yes ! No 1 NA <br /> Was sensor properly replaced and No res - - NA Yes No NA <br /> verified functional after testing? Yes No NA YNo NA es Y <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> The sensor was reinstalled to the lowest point,but not tested. <br /> i <br /> i <br /> E <br />