Laserfiche WebLink
0 <br /> Appendix VI 10 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboREPEIVED <br /> a. .) <br /> MONITORING SYSTEM CERTIFICATION APR 09 '1014 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code,Chapter 16,Division 3, Tule 23,California Code ofRegulati ��® <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report mus 1 t <br /> monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank e <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co. dba AT&T California Building No.: UE020 <br /> Site Address: 124 W. ELM ST. City: Lodi Zip: 95240 <br /> Facility Contact Person: Dave Dube Contact Phone No.: 209-474-4022 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 plus Date of Testing/Servicing: 3/27/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: UE020U001 Tank ID: UE020A003 <br /> In-Tank Gauging Probe. Model: 847390-107/439514 F In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 794390420/441672 r Annular Space or Vault Sensor. Model:794380-344/844409 <br /> Piping Sump/Trench Sensor(s). Model: 794380-208/685112 F Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 794380-208/657586 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 790091-001 Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: F hi-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: tl Piping Sump/Trench Sensor(s). Model: <br /> F Fill Sump Sensor(s). Model: F Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: F Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> .Dispenser ID: Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). F Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> F Dispenser Containment Sensor(s). Model IF Dispenser Containment Sensor(s). Model: <br /> F Shear Valve(s). F Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). F Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correctand <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) : F System set-up F Alarm history report <br /> Technician Name(print): Victor Guerrero r <br /> Signature: <br /> Certification No.: B36532 License.No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 SOUTH DUPONT DRIVE.arrrirmKCA92806 Date of Testing/Seryicing: 3/27/2014 <br />