Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> Software Version Installed: 122.0 <br /> Complete the following checklist: <br /> _----- <br /> i....._.. ......_. _ .. <br /> F Yes ITr- No* Is the audible alarm operational? <br /> F Yes No* Is the visual alarm operational? <br /> I Yes F No* (Were all sensors visually inspected,functionally tested and confirmed operational? <br /> � *� 1 Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> � Yes � � No equipment <br /> will not interfere with their <br /> ro r o ration? <br /> a <br /> Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> N/A operational? <br /> F Yes F No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary <br /> containment monitoring system detects a leak,fails to operate, or is electrically disconnected?If yes:which <br /> N/A sensors initiate positive shut-down?(Check all that apply) <br /> Sump/Trench Sensors; F Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to I eaks and sensor failure/disconnection? <br /> Yes� No Yes � No* For tank systems that utilize the monitoring system as the primary tank overfill waming device(i.e.no <br /> � <br /> N/A I mechanical overfill prevention valve is installed),is the overfill waming alarm visible and audible at the <br /> tank fill point(s) and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> .. �0 <br /> F Yes* ; ' No Was any monitoring equipment replaced. If yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E below. <br /> Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br /> ` apply) F Product; F Water.If yes,describe causes in Section E,below. <br /> Yes f No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports if applicable <br /> Yes F No* Is all monitoring equipment operational per manufacturers specifications? <br /> *Iii Section below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Other sensors from page one: <br /> L-4 Generator Room 794380-208 Certified <br /> L-5 Fire Box 794380-208 Certified <br /> C-1 Belly Tank Annular 794380-344 Certified <br />