COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are present,but were Not Tested r <br /> Test Method Developed By: Sump Manufacturer F Industry Standard r— Professional Engineer <br /> rOther(Specify) <br /> Test Method Used: F Pressure r— vacuum 17' Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Incon TS-STS E ui ment Resolution: .0006 <br /> ill Sump Fill S ump Fill Sump ill Sump <br /> LIE020U001 <br /> Sump Diameter: 40" <br /> 7 <br /> Sump Depth: 46" <br /> Height from Tank Top to Top of n/a <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 17„ <br /> Electrical Penetration: <br /> Condition of sump prior to Good <br /> testing : <br /> Portion of Sump Tested: 2" above collar <br /> Sump Material: Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 min <br /> starting test: <br /> Test Start Time: 11:25 am 11:41 am <br /> Initial Reading(RI): 2.2894 2.2893 <br /> Test End Time: 11:40 am 11:56 am <br /> Final Reading(RF): 2.2893 2.2892 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF'R1): .0001 .0001 <br /> Pass/FaiI Threshold or Criteria: 0.002 0.002 <br /> Test Result: F Pass F Fail r— Pass r— Fail r— Pass F Fail y Pass F Fail <br /> 1- <br /> Is there a sensor in the sump? Yes r— No F Yes r— No r— Yes r g <br /> No 9 Yes 1 No <br /> Does the sensor alarm when either Yes , No r NA Yes No NA Yes No NA F Yes x" '' NA <br /> product or water is detected? g r p p— <br /> Was sensor removed for testing? I_ Yes r No 1 NA r Yes No r NA 1 Yes 7 No r NA r Yes 1 No r NA <br /> Was sensor properly replaced and (— j` - NA Yes No NA <br /> verified functional after testing? Yes r No r NA Yes No NA Yes No <br /> Comments (include information on repairs made prior to testing, and recommended follow up for failed tests) <br /> jReinstalled sensor at lowest point but not tested. <br />