PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_1994-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> SWRCB,January 2002 Page_2_of_2_ <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ®Tank Manufacturer ®Industry Standard Professional Engineer <br /> Other(Specify) <br /> Test Method Used: Pressure ®Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: DIGITAL MANOMETER Equipment Resolution: N/A <br /> EMEENEEM <br /> Tank#1052 Tank# Tank# Tank# <br /> son=-- <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Tank Capacity: 25,018 <br /> Tank Material: FIBER-STEEL <br /> Tank Manufacturer: MODERN <br /> WELDING <br /> Product Stored: RED DIESEL <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MINUTES <br /> starting test: <br /> Test Start Time: 8:35 A.M. <br /> Initial Reading(RI): 7"HG <br /> Test End Time: 9:35 A.M. <br /> Final Reading(RF): 7"HG <br /> Test Duration: 1 HOUR <br /> Change in Reading(RF-R,): 0"HG <br /> Pass/Fail Threshold or Criteria: +0"HG <br /> Test Result: 0 Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ®Yes No NA ❑Yes No NA ❑Yes No NA ❑Yes No NA <br /> Was sensor properly replaced and ®Yes No NA ❑Yes No NA ❑Yes No NA ❑Yes No NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> *Annular passed the tank manufacturer's recommended vacuum test. <br /> No repairs are needed at present time. <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)} <br />