My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:21:17 PM
Creation date
6/3/2020 9:53:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7 Health andSafety Code,Chapter 16,Division 3, Title 23,California Code ofRegulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certificationor report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co. dba AT&T California Building No.: UE042 <br /> Site Address: 345 N.SAN JOAQUIN City: Stockton Zip: 95202 <br /> Facility Contact Person: Connie Mitchell Contact Phone No.: 209-598-5155 <br /> Make/Model of Monitoring System: Veeder Root TLS350 Date of Testing/Servicing: 4/19/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tan �,,, r w__�__�_�;;,�-_„ _—���_ _..._.� .__ ..._� <br /> k ID: UE042U001 Tank ID <br /> F In-Tank Gauging Probe. Model: 847390-109 F In-Tank Gauging Probe. Model: <br /> W Annular Space or Vault Sensor. Model:794390420 Annular Space or Vault Sensor. Model: <br /> R' Piping Sump/Trench Sensor(s). Model: 794380-208 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 794380-208 F Fill Sump Sensor(.). Model: [ <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> F Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> F Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: <br /> Tank ID <br /> In-Tank Gauging Probe. Model: F In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: F Annular Space or Vault Sensor. Model: <br /> F Piping Sump/Trench Sensor(s). Model: F Piping Sump/Trench Sensor(s). Model: <br /> F Fill Sump Sensor(s). Model: F Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> F Tank Overfill/High-Level Sensor. Model: F Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> F Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). F Shear Valve(s). <br /> !F Dispenser Containment Float(s)and Chain(s). 4 F Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensogs). Model: <br /> Shear Valve(s). r Shear Valve(s). <br /> F Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks ordispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> * <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) : P System set-up R Alarm history report <br /> Technician Name(print): Tim Minard <br /> Signature: <br /> Certification No.: B36222 License.No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 SOUTH DUPONT DRIVE ANAHEIn-t,cn92806 Date of Testing/Sery icing: 4/19/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.