My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:33:21 PM
Creation date
6/3/2020 9:53:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In -Tank Gauging / SIR Equipment: SEP 181 <br />% Check this box if tank gauging is used only for inventory control. <br />Check this box if no tank gauging or SIR e i ' <br />, ft- HEALTH <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. . k� w <br />ENT <br />*In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): P Check this box if LLDs are not installed. <br />Complete the following checklist: <br />r YesF <br />No* <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance?(Check <br />N/A <br />all that apply) Simulated leak rate: F 3 g p.h.; F 0.1 g. p. h ; r— 02 g.p.h. <br />F Yes <br />F No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />• Yes <br />F No* <br />Was the testing apparatus properly calibrated? <br />Yes <br />FNo* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />N/A <br />• Yes <br />r No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />r' N/A <br />• Yes <br />r No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or <br />r— N/A <br />disconnected? <br />Yes <br />• No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions• or <br />N/A <br />fails a test? <br />Yes <br />F No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />N/A <br />F Yes <br />F No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />N VY <br />* r will be erected. <br />IntheSection H, below, descrbehow and when these deficiencies were e oo„ <br />H. Comments: <br />System. <br />
The URL can be used to link to this page
Your browser does not support the video tag.