My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:33:21 PM
Creation date
6/3/2020 9:53:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> f <br /> SWRCB,January 2002 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer Q Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum f-x�Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> Fill Sump UE040001 <br /> Sum Diameter: 38" <br /> Sump Depth: 40" <br /> Height from Tank Top to Top of 10" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 8„ <br /> Electrical Penetration: <br /> Condition of sump prior to Good <br /> testing: <br /> Portion of Sump Tested 2"above piping <br /> Sump Material: Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min. <br /> starting test: <br /> Test Start Time: 9:25am 9:40am <br /> Initial Reading(RI): 3.9564 3.9560 <br /> Test End Time: 9:40am 9:55am <br /> Final Reading(RF): 3.9560 3.9559 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF-Rj): .0004 .0001 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: ❑X Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? ❑X Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑1'es [E]No ❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> detected? <br /> Was sensor removed for testing? ❑X Yes ❑No ❑NA ❑Yes❑No❑NA F-1 Yes❑No❑NA El Yes El No El NA <br /> Was sensor properly replaced and ❑Yes IK No ❑NA <br /> verified functional after testing? ❑Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor was removed for testing, but not tested and was reinstalled to the lowest point. <br />