My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:33:21 PM
Creation date
6/3/2020 9:53:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> AUG 2 3 201 <br /> SWRCB,January 2002 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING ENVIRONMENTAL <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ HEALTH Q <br /> EPARTME <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer Q Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon ST-STS Equipment Resolution: .0006 <br /> Fill Sump UE040001 Center UE040001 <br /> Sump Diameter: 38" 38" <br /> Sump Depth: 40" 40" <br /> Height from Tank Top to Top of 10" N/A <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 8" 8" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good <br /> testing: <br /> Portion of Sump Tested 2"above piping 2"above collar <br /> Sump Material: Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and Visual failure 15 min <br /> starting test: <br /> Test Start Time: 9:37am 9:54am <br /> Initial Reading(RI): 3.4054 3.4050 <br /> Test End Time: 9:52am 10:09am <br /> Final Reading(RF): 3.4051 3.4049 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF-RI): .0003 .0001 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: ❑Pass ❑X Fail ❑X Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? ❑X Yes ❑No ❑X Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when ❑Yes [Z]No ❑NA <br /> either product or water is ❑Yes❑X No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> detected? <br /> Was sensor removed for testing? [::]Yes [E]No ❑NA ®Yes❑No❑NA ❑Yes❑No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ❑Yes EK:]No ❑NA <br /> verified functional after testing? ❑Yes❑No 0NA ❑Yes : No INA ❑Yes❑No❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor was removed for testing and reinstalled to the lowest point, but not tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.