My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:33:21 PM
Creation date
6/3/2020 9:53:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> SWRCB,January 2002 AUG 2 3 201 <br /> 6. PIPING SUMP TESTING ENVIRONMENIAI <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑ProldfiftTHEDOWTMENT <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> Piping UE0420001 <br /> Sump Diameter: 38" <br /> Sump Depth: 41" <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 15" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 10" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good <br /> Portion of Sump Tested' 2"above piping❑No ONA <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑Yes❑No DNA ❑Yes❑No DNA ❑Yes❑No❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail-safe ❑Yes ❑No ❑X NA <br /> ❑Yes❑No DNA ❑Yes❑No ❑NA ❑Yes[--]No DNA <br /> shutdown? <br /> Was fail-safe verified to be ❑Yes ❑No ❑X NA <br /> ❑Yes❑No DNA ❑Yes❑No DNA ❑Yes❑No❑NA <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 min. <br /> test: <br /> Test Start Time: 9:37am 9:54am <br /> Initial Reading(Ri): 3.0815 3.0789 <br /> Test End Time: 9:52am 10:09 <br /> Final Reading(RF): 3.0802 3.0781 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF-RI): .0013 .0008 <br /> Pass/Fail Threshold or Criteria: .002 1.002 <br /> Test Result: ❑X Pass ❑Fail ❑ Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? [E]Yes ❑No DNA ❑Yes[—]No DNA ❑Yes❑No DNA ❑Yes❑No DNA <br /> Was sensor properly replaced and ❑Yes 0No DNA <br /> verified functional after testing? Dyes[—]No DNA ❑Yes❑No DNA ❑Yes❑No DNA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensors was removed for testing and reinstalled to the lowest point, but not tested. <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to as of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.