My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps r <br /> Fill Riser Containment Sumps are present,but were Not Tested r <br /> Test Method Developed By: j"Sump Manufacturer r Industry Standard Professional Engineer <br /> Other(Specify) <br /> Test Method Used: F Pressure r Vacuum W Hydrostatic <br /> r-Other(Specify) <br /> Test Equipment Used: INCON TS-STS Equipment Resolution: .0006 <br /> Fill Sump Fill S ump Fill Sump Fill Sump <br /> UE058UO02 <br /> Sump Diameter: 38" <br /> Sump Depth: 45" <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: N/A <br /> Height from Tank Top to Lowest 26„ <br /> Electrical Penetration: <br /> Condition of sump prior to Good <br /> testing : <br /> Portion of Sump Tested: 2" above high pen. <br /> Sump Material: Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min. <br /> starting test: <br /> Test Start Time: 9:04 am 9:20 am <br /> Initial Reading(Rt): 1.2561 1.2554 <br /> Test End Time: 9:19 am 9:35 am <br /> Final Reading(Rd: 1.2555 1.2551 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF.Rt): .0006 .0003 <br /> Pass/Fai I Threshold or Criteria: .002 .002 <br /> Test Result: r' Pass Fail Pass Fail r Pass r-Fail F Pass r-Fail <br /> Is there a sensor in the sump? r Yes No Yes r- No r- Yes F No F Yes No <br /> Does the sensor alarm when either F Yes F No r NA r- Yes r- No r NA r- Yes r- No r NA r- Y. r No r NA <br /> product or water is detected? p p g p p <br /> Was sensor removed for testing? P Ym f No r NA f Yes 1 No I NA Yes 9 No r NA 1 Yes 6 No 1 NA <br /> Was sensor properly replaced and y <br /> g p— y � g @� <br /> verified functional after testing? I Yes R No f NA Ya r No i NA 1 Yes ! No f NA 8 Yes r No r'. NA <br /> COt1=eutS-(include information on repairs made prior to testing, and recom mendedfollow-up for failed tests) <br /> ;The sensor was reinstal led to the lowest point,but not tested <br /> i <br /> ................... .. �.. ... . _.�... _..._. _. ._... �__ .._.w..... _....._ _. .__�. �_.._�__. . <br />
The URL can be used to link to this page
Your browser does not support the video tag.