My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code ofRegulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co. dba AT&T California BuildingNo.: UE058 <br /> Site Address: 10 E. 12TH ST. City: Tracy Zip: 95376 <br /> Facility Contact Person: Connie Mitchell Contact Phone No.: 209474-4022 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 4/25/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: UE05 8UO02 s Tank ID: <br /> i✓ In-Tank Gauging Probe. Model: 847390-107 F In-Tank Gauging Probe. Model: <br /> F Annular Space or Vault Sensor. Model: 794390420 r Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: 794380-208 F Piping Sump/Trench Sensor(s). Model: <br /> i✓ Fill Sump Sensor(s). Model:794380-208 F Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> F Tank Overfill/High-Level Sensor. Model: 790091-001 r— Tank Overfill/High-Level Sensor. Model: <br /> F'' Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID• <br /> In-Tank Gauging Probe. Model: F In-Tank Gauging Probe. Model: <br /> I— Annular Space or Vault Sensor. Model: F Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model F Piping Sump/Trench Sensor(s). Model: <br /> r— Fill Sump Sensor(s). Model: F Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: F Tank Overfill/High-Level Sensor. Model: <br /> F Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> F Dispenser Containment Sensor(s). Model r Dispenser Containment Sensor(s). Model: <br /> F Shear Valve(s). F Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> F Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensor(s). Model: <br /> F Shear Valve(s). r— Shear Valve(s). <br /> F Dispenser Containment Float(s)and Chain(s). F Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks ordispensers,copy this form.Include information for every tank and dispenser at the facility. �.... <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certificatron is information(e g.manufacturers' checklists)necessary to verify that this information is correct and <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) F System set-up r Alarm history report <br /> Technician Name(print): John Cascio <br /> Signature: <br /> Certification No.: B35337 License.No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 sOUTHDUPONTDRIVE,ANAHBNLCA92806 Date of Testing/Servicing: 4/25/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.