COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> Software Version Installed: 121.00 <br /> Complete the following checklist: <br /> F7 <br /> ._._, No* Is the <br /> Yes audible alarm operational? <br /> Yes No* Is the visual alarm operational? <br /> F Yes F No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> w. <br /> Yes F No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> ro r o ration? <br /> F Yes F No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> F N/A operational? <br /> F Yes F No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> F N/A containment monitoring system detects a leak,fails to operate, or is electrically disconnected?If yes: which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> F sump/TrenchSensors; Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to 1 eaks and sensor failure/disconnection? <br /> Yes; F No. <br /> r— Yes F No* For tank systems that utilize the monitoring system as the primary tank overfill waming device(i.e. 7the <br /> mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible a <br /> r N/A tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> EF Yes* No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ;,r.;,;... ._ w.� ;:..;:� __ _ _ <br /> I Yes* 1—v No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br /> { apply) F Product; F Water.If yes,describe causes in Section E,below. <br /> Yes No* (Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> � Yes � No* Is all monitoring equipment operational per manufacturer's specifications? <br /> �In Section E below,describe how and when these deficiencies were or will b <br /> .�.......�.._.be corrected <br /> E. Comments: <br /> Other Sensors From Page 1: <br /> L4 Generator Room Floor Sensor 794380-208-Certified <br /> An Overfill Prevention Valve Is Located In The Drop Tube. <br />