My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> Software Version Installed: 121.00 <br /> Com tete the followin checklist: <br /> tYes F No* Is the audible alarm operational? <br /> F Yes F No* Is the visual alarm operational? <br /> r Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Yes r No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> proper operation? <br /> * Yes r No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> F N/A operational? <br /> Yes r No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary <br /> F N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> F Sump/Trench Sensors; r Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> F Yes; FNo. <br /> * Yes F No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> F Yes* F No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> Yes* F No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br /> apply) F Product; F Water.If yes,describe causes in Section E,below. <br /> • Yes r No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> • Yes F, No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section below,describe how and when these deficiencies were or will he corrected <br /> E. Comments: <br /> Other sensor from Page 1: <br /> (L4)Gen.Room Floor:794380-208/certified <br /> An Overfill Prevention Valve is installed in the drop tube. <br />
The URL can be used to link to this page
Your browser does not support the video tag.