Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:23:59 AM
Creation date
6/3/2020 9:54:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_1998-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLC-5000 Site Controller, LD-2000 and LD-2000 PLC <br /> Table 2. Performance Parameters for the Vaporless PLC-5000 Site Controller <br /> with Automatic Electronic Line Leak Detection and the 98 LD-2000 <br /> and 98 LD-2000 PLC <br /> Parameter Value <br /> Abbreviated Hourly Testing (3.0 gal/h leaks) <br /> Threshold 2.5 gal/h <br /> Probability of Detection (PD) 100% <br /> Probability of False Alarm (PFA) 0% <br /> Test Times with 3.0 gal/hr leak Range: 1 to 8 minutes <br /> Test Times without leak Range: < 1 minute <br /> Monthly Monitoring/Annual Line Tightness Testing (0.1 gal/h leaks) <br /> Threshold a 0.068 gal/h <br /> Probability of Detection (PD) 100% <br /> Probability of False Alarm (PFA) 0% <br /> Test Times with 0.1 gal/hr Leak Range: 3.5 to 9.2 hours <br /> Average: 6 hours <br /> Test Times without Leak Range: 1.8 to 10.9 hours <br /> Average: 5.3 hours <br /> Maximum Rigid Pipeline Size 400 ft of 3.25 in diameter <br /> line or 172 gal volume <br /> Maximum Flexible Pipeline Size 415 ft of 1.5 in diameter <br /> line or 39.5 gal volume <br /> Waiting Time After Delivery of <br /> Product Before Conducting a Test None Required <br /> Waiting Time After Product Circulation <br /> Through Line Before Conducting a Test None Required <br /> 8 The commercial version of the system will provide Monthly Monitoring for 0.2 gal/h leaks using <br /> a threshold at 0.136 gal/h. However, Monthly Monitoring for 0.2 gal/h leaks was not tested by KWA, Inc. <br /> Tests with leak rates of 0.1 gal/h were simulated and were detected by the system when the threshold <br /> was set at 0.068 gal/h. The system correctly identified 100% of the 0.1 gal/h leak simulations and it is <br /> therefore assumed that the system will correctly identify 0.2 gal/h leaks using a threshold of 0.136 gal/h. <br /> Page 10 <br />