COMPLIANCE INFO_1998-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:23:59 AM
Creation date
6/3/2020 9:54:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_1998-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLC-5000 Site Controller, LD-2000 and LD-2000 PLC <br /> 7.0 Conclusions <br /> The following conclusions and recommendations are based on the results of the testing <br /> described in this report. <br /> • The Vaporless PLC-5000 Line Leak Detection system exceeds the EPA <br /> performance requirements for Hourly Testing and Annual Line Tightness Testing. <br /> • In the Monthly Monitoring/Annual Line Tightness Testing mode, the probability of <br /> detection (Po) ofa 0.1 gal/hr leak is 100% and the probability of false alarm on a <br /> tight line is 0%. (The EPA requires apDof at least 95% and a PFAofno greater <br /> than 5%.) <br /> • The system performed properly for the six Monthly/Annual tests conducted on <br /> the flexible pipeline. <br /> • The 98 LD-2000/98 LD-2000 PLC performed properly for the 19 Hourly tests that <br /> were conducted on the rigid and flexible pipelines. <br /> • The Vaporless system can be used on rigid pipelines up to 172 gallons in volume <br /> or 400 feet of 3.25 inch diameter line. <br /> • The Vaporless system can be used on flexible pipelines up to 39.5 gallons in <br /> volume or 430 feet of 1.5 inch diameter line. <br /> • A waiting time after product is circulated through the line or after pumping has <br /> stopped is not necessary before conducting a valid test. Testing was initiated <br /> immediately following the product circulations. <br /> • A waiting time after delivery of product is not necessary before a valid test can <br /> be conducted. <br /> Page 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.