COMPLIANCE INFO_2004-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2004-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2024 4:32:43 PM
Creation date
6/3/2020 9:54:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2012
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2004-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
417
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,SWRCB, January 2002 0 <br />4. TANK ANNULAR TESTING <br />0 Page 2 of 6 <br />Test Method Developed BY: 11 Tank Manufacturer N Industry Standard El Professional Engineer <br />0 Other (Specify) <br />Test Method Used: El Pressure A( Vacuum El Hydrostatic <br />1:1 Other (Specify) <br />Test Equipment Used: VACCUM GAUGE <br />Equipment Resolution: "HG <br />-7- <br />Tank # 87 <br />ME <br />Tank # 91/DSL <br />Tank # <br />Tank # <br />Is Tank Exempt From Testing?' <br />El Yes XNo <br />11 Yes XNo <br />11 Yes 11 No <br />El Yes L1 No <br />Tank Capacity: <br />12K <br />12K <br />Tank Material: <br />FIBERGLASS <br />FIBERGLASS <br />Tank Manufacturer: <br />UNKNOWN <br />UNKNOWN <br />Product Stored: <br />GAS <br />GAS/DIESEL <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5 MIN <br />5 MIN <br />Test Start Time: <br />1039 <br />1039 <br />Initial Reading (Ri): <br />101, <br />101, <br />Test End Time: <br />1139 <br />1139 <br />Final Reading (RF): <br />91, <br />91, <br />Test Duration: <br />IHR <br />I HR <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />2" <br />2" <br />Test Result: <br />0 Pass 0 Fail <br />4 Pass 0 Fail <br />0 Pass El Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />f Yes El No El NA <br />Yes 0 No El NA <br />L1 Yes El No 7— NA <br />11 Yes El No 0 NA <br />Was sensor properly replaced and <br />verified functional after testing? I <br />J4 Yes 11 No 11 NA <br />K Yes El No Ej NA <br />I <br />El Yes El No El NA <br />I <br />11 Yes 11 No [I NA <br />Comments —(include information on repairs made prior to testing, and recommended allow -up for failed tests) <br />911DSL IS A SPLIT TANK <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, e exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />