My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />76 MINI MART <br />1001 E YOSEMITE AVE, MANTECA <br />February 18, 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />111 <br />CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br />Annual monitoring system certification and leak detector testing were last performed on January 16, 2014 and was <br />due by January 16, 2015. Testing has not been completed and is past due. These tests are required once every 12 <br />months. Immediately schedule these tests and provide a 48 -hours notification to the EHD. Please be aware that a <br />follow up inspection will be charged at our current hourly rate. This is a Class II violation. <br />112 <br />HSC 25284.2 Failed to test spill containers annually. <br />Annual spill container testing was last performed on January 16, 2014 and was due by January 16, 2015. Testing <br />has not been completed and is past due at this time. This test is required once every 12 months. Immediately <br />schedule this test and provide 48 hours notification to the EHD. Please be aware that a follow up inspection will be <br />charged at our current hourly rate. This is a Class II violation. <br />114 <br />CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down. <br />Based on the results of the most recent monitoring system certification, conducted on January 16, 2014, the diesel <br />UST is not fail safe and does not meet the requirements of the annual line tightness testing exemption. Due to a <br />malfunctioning diesel turbine, the failsafe operation of diesel UST could not be verified during the January 16, 2014 <br />immediately. Immediately schedule this test to verify fail safe operation, and provide a 48-hour notice to the EHD. <br />This is a minor violation. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. This is a minor violation. <br />208 <br />CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The January 2015 designated operator monthly inspection reports were not found on site, according to the site <br />operator the facility has been in operation as of January 9, 2015. Designated operator monthly inspection reports <br />for the previous twelve months shall be retained on site. Ensure that copies of the previous twelve months of <br />designated operator monthly inspection reports are maintained on site. According to Mr. Singh (the site operator) <br />no designated operator inspection was conducted in January of 2015. This is a minor violation. <br />209 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />According to Mr. Singh, the designated operator employee training was not performed for this facility. The <br />designated operator shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. This is a minor violation. <br />Received by (initial): I r: <br />Phone: <br />Date: <br />�-- ELENA MANZO, REHSy <br />(209) 953-7699 <br />02/18/2015 <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.