My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.orq/ehd <br /> Underground Storag> Taink,jP»ograirn Irpectior:.Rep <br /> ort; <br /> Facility Name: Facility Address: Date: <br /> DINO MART 1001 E YOSEMITE AVE, MANTECA January 31, 2018 <br /> SUMMARY OF UIOLATIONS� <br /> ;, (CLASS I CE ASS II M <br /> or otice IMOR Nto Comply , <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information for the 87 grade, 91 grade and Diesel tanks are not current in CERS. <br /> In CERS, for the 87 grade and 91 grade tanks,vent piping is listed as having secondary containment fiberglass and <br /> vapory recovery was listed as having no piping for primary or secondary containment. Both the vent and the vapor <br /> recovery piping were observed as primary fiberglass with no secondary containment. <br /> In CERS,for the Diesel tank, vent piping is listed as having secondary containment fiberglass. The vent piping was <br /> observed as primary fiberglass with no secondary containment. <br /> This violation was written in the 4/3/2017 inspection report and has not been corrected. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and not approved by the EHD. <br /> For all three tanks, under"training", NO is marked for <br /> "Personnel with UST Monitoring Responsibilities are Familiar with Training Documents." This statement needs to <br /> be marked YES as is required with DO training. <br /> This violation was written in the 4/3/2017 inspection report and has not been corrected. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 113 CCR 2638(d)Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 4/3/2017 <br /> and a test report was submitted on 1/19/2017 , approximatly 9 months late. A copy of the test report must be <br /> submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br /> are performed in a timely manner. <br /> This is a Class II violation. <br /> 120 CCR 2635(d)Failed to submit UST Certification of Installation/Modification. <br /> The diesel underground fiberglass fitting located adjacent to under dispenser containment unit 3/4 was replaced <br /> under permit number SR0072496 and the UST Certification of Installation/Modification has not been submitted. The <br /> certification is required to be submitted within 30 days of completion of work to the California Environmental <br /> Reporting System(CERS). Immediately log into CERS, complete the required information,and submit for review by <br /> the EHD. <br /> This is a repeat violation, Class II. <br /> FA0000421 PR0231876 SCO01 01/31/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 7 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.