My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si4ov.org/ehd <br /> s : <br /> Underground Storage-Tank¢,Program 1q pection Report <br /> Facility Name: Facility Address: Date: <br /> DINO MART 1001 E YOSEMITE AVE, MANTECA January 31,2018 <br /> .i SUMMARY OF VIOLATIONS <br /> (CLASS 1 CLASS II,ocN(F[OR-Notice to Comply) <br /> Item# Remarks <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Liquid was observed pooling on the bottom of the filter with a wet surface seen directly below the filter in the 7/8 <br /> under dispenser containment unit. Immediately fix the problem and send proof of correction to the EHD. <br /> Monthly overfill alarms(for the T1 UST tank)have been noted from March 2017 through January 2018. The <br /> monthly underground storage tank system shall be operated to prevent unauthorized releases and overfills. Ensure <br /> that the T1 tank system is not being routinely overfilled and that the required overfill prevention is being maintained. <br /> Take all necessary precautions to prevent this in the future. Note:the overfill alarms are a repeat violation. <br /> Designated operator has mentioned several times to"stop fuel delivery as soon as the first alarm (overfill)goes <br /> off."-8/1/2017 designated operator monthly inspection report. <br /> This is a repeat violation, Class II. <br /> 309 CCR 2636(f)(1)Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain for the 87 grade piping in the 1/2 UDC sump and the 87 grade and 91 grade in the <br /> 3/4 UDC sump failed to stop the flow of product at the dispenser when tested. All monitoring equipment shall be <br /> maintained to activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a <br /> leak. The service technician cleared debris, adjusted the chains, and verified functionality. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Violations taken off checklist: <br /> 209, 211 <br /> Report was emailed with a list of free EHD classes and a recordable release document. <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: February 26,2018 Inspector. Inspector Phone: <br /> Printed Name and Title: JOHN ALANIZ, EH Specialist (209)468-3147 <br /> Sent Via Email, <br /> FA0000421 PR0231876 SCO01 01/31/2018 <br /> EHD 23-01 Rev.09/22/16 Page 7 of 7 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.