My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKHEED
>
1941
>
2300 - Underground Storage Tank Program
>
PR0231891
>
COMPLIANCE INFO_1987-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 2:13:15 PM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2006
RECORD_ID
PR0231891
PE
2361
FACILITY_ID
FA0003674
FACILITY_NAME
BANK OF STKN AIRPORT HANGAR #3
STREET_NUMBER
1941
Direction
E
STREET_NAME
LOCKHEED
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
1941 E LOCKHEED CT
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231891_1941 E LOCKHEED_1987-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
so <br />SAN j0AQUIN LOCAL HEASjTH DI SrrRI Crr <br />SAMPLING PROTOCAL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil <br />samples collected shall be representative of native soils beneath the tank's <br />invert (tank's bottom] at a collection depth not be exceed 2 - 4 feet. If contamination <br />is documented during closure an Unauthorized Release notification must be filled out and <br />submitted to SJLHD within 5 days. Section 2652, CCR. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK SIZE MINIMUM NUMBER �OF LOCATION OF SOIL SAMPLES <br />SOIL SAMPLES <br />Less than 1000 gallons ONE per tank Fill or pump end of tank <br />000 - 10,000 gallons TWO per tank One at each end of tank <br />tl 10,001 gallons and up THREE OR MORE Ends and Middle or <br />per tank enerall spaced along <br />?he length of the tank <br />Piping ONE EVERY 20 LINEAL FEET <br />WATER IS PRESENT IN -TANK PIT <br />TANK SIZE MINIMUM NO. OF <br />SOIL SAMPLES <br />LOCATION OF SOIL <br />SAMPLES <br />MINIMUM NUMBER <br />OF WATER SAMPLES <br />10,000 GALLONS � <br />From wall next to <br />OR LESS <br />tank ends at soil/ <br />(Single Tank) TWO <br />groundwater <br />ONE <br />interface <br />GREATER THAN <br />From wall next to <br />ONE <br />10,000 GALLONS <br />tank ends.at soil/ <br />OR <br />groundwater <br />TANK CLUSTER FOUR <br />interface <br />orrHE R, SPECIAL G(DNDI'I'I(DNS <br />SLAB PRESENT IN TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration throu h <br />the obstruction will be required in order to collect the samples. (Physical removal of the <br />obstruction will then allow sampling according to the above conditions.) <br />~+ TANK SIZEM~Y_.__ MINIMUM NUMBER OF LOCATION OF SOIL SAMPLES <br />SOIL SAMPLES <br />Less than 1000 gallons THREE per tank Center and ends or sides <br />1000 - 10,000 gallons FIVE per tank Center and ends or sides <br />10,001 gallons and up FIVE OR MORE per Ends and Middle and <br />tank enerally spaced along <br />?he length of the tank <br />EH 23 047 12/88 <br />REVISED 1/89 <br />