My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKHEED
>
1941
>
2300 - Underground Storage Tank Program
>
PR0231891
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 3:00:31 PM
Creation date
6/3/2020 9:54:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231891
PE
2361
FACILITY_ID
FA0003674
FACILITY_NAME
BANK OF STKN AIRPORT HANGAR #3
STREET_NUMBER
1941
Direction
E
STREET_NAME
LOCKHEED
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
1941 E LOCKHEED CT
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231891_1941 E LOCKHEED_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
00 R"IVED <br />SWRCB, January 2002 JUL 13 2015 Page 6 Of 7 <br />8. FILL RISER CONTAINMENT <br />Facift is Not Equipped With Fill Riser Containment Sums PER ITES <br />Fill Riser Containment Sumps are Present, but were Not Tested i <br />Test Method Developed By: Cl Sump Manufacturer 7andustry Standard U Professional Engineer <br />U Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />Other (Spec) <br />Vacuum FXHydrostatic <br />Test Equipment Used: <br />Equipment Resolution: <br />Sump Diameter <br />Fell Sump # <br />48" <br />FiH Sump # Fill Sump # Fill Sump # <br />Sump Depth: <br />W. <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />15" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />Condition of sump prior to <br />testing: <br />GOOD <br />Portion of Sump Tested <br />Sump Material: <br />FIBER <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 <br />Test Start Time: <br />1:00 <br />Initial Reading Rt : <br />1 CIRCLE <br />Test End Time: <br />1:30 <br />Final Readin (RF): <br />1 CIRCLE <br />Test Duration: <br />30 RAIN <br />Change in Reading (Rp-RI): <br />0 <br />Pass/Fail Threshold or Criteria: <br />+1.00025" <br />Test Result: <br />X P Fail <br />Pass f3 Fail _, Pass i Fail .? Pass It, Fail <br />Is there a sensor in the sum E. <br />Yes ❑ No <br />f 3 Yes i No i Yes U No U Yes U No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />X Yes ; I No 1.1 NA <br />i _': Yes U No ❑ NA U Yes U No U NA U Yes U No C:1 NA <br />Was sensor removed for testing? <br />O(Yes 0 No CI NA <br />!J Yes U No !_INA Yes U No U NA IF Yes U No U NA <br />Was sensor properly replaced and X Yes F1 No 1 NA U Yes '--No U i NA CJ Yes N No UNA C7 Yes Ci No [-INA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing and recommendedfollow-up)brfailed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.